10-way connector (CN1)
Connector CN1 is used to connect the non-
contact unit to the NCi-4 interface. The interface
automatically detects which NC unit has been
connected.
15-way connector (CN2)
Connector CN2 is used to connect the NCi-4
interface to the CNC machine tool.
Terminals 1 – 2
Used to monitor the signal from the NC3 or NC4.
Terminals 3 – 6
These are SSR outputs that can be used to
control external devices. Devices may include a
LED or a buzzer.
An output can also be used with an NC1
separate system and NC4 systems to switch the
transmitter unit on/off independently of the
receiver. Alternatively, it can act as a skip-

Connectors CN1 and CN2

sharing module to switch between a non-contact
tool setting device and an OMI/MI12 for spindle
probing. This output is fused at 200 mA.
Terminals 7 – 8
This is an SSR output that can be configured to
be either normally-open (N/O) or normally-closed
(N/C). The output is fused at 50 mA.
Terminals 9 – 10
This is an SSR output that can be configured to
be either normally-open (N/O) or normally-closed
(N/C), as well as providing a level or pulsed
output. The output is fused at 50 mA.
Terminals 11 – 12
This is used to select the operating mode.
Terminals 13 – 15
This is used to supply power to the interface.