This signal word indicates important information that prevents damage to property. Dieses Symbol kennzeichnet nützliche Tipps, Empfehlungen sowie zusätzliche Informationen. This symbol indicates useful tips, recommendations and addi- tional information. Dieses Symbol kennzeichnet Handlungsanweisungen. This symbol indicates instructions. AK MS 45...
Teilungsperiode / Grating period S. resolution 4 × Interpolation / Interpolation Messschritt 200 µm = 0,5 µm S. resolution 4 × 100 AK MS 45: 0.200µs: Produktname / Product name Referenzmarke Flankenabstand a Reference mark Edge separation a A: Aktiv / Active...
Seite 5
Technische Daten / Technical data 2 2.2 ABMESSUNGEN / DIMENSIONS AK MS 45...
Lay the cable from the scanning head to the control in such a way that it does not get caught up in operation when moving along the machine travel; it is not crushed, kinked or otherwise damaged; it does not run directly alongside power lines. AK MS 45...
Demands for mounting see in dimensions (see page 05). Referenzmarke Reference mark 4.3 STÖRQUELLEN / SOURCES OF INTERFERENCE Halten Sie den Mindestabstand von Störquellen ein. Keep minimum distance from sources of interference. ≤ 30 000 mm > 100 mm > 100 mm > 200 mm Störquellen Noise sources AK MS 45...
5.1 GERÄT AUSPACKEN / UNPACK ENCODER 5.2 SCHUTZFOLIE ABZIEHEN / STRIP AWAY PROTECTION FOIL Beschädigungsgefahr durch spitzes Werkzeug! HINWEIS MONTAGEANLEITUNG MOUNTING INSTRUCTIONS AK MS 45 Abtastkopf Die Abtastplatte ist hochsensibel und kann durch Kratzer beschädigt Scanning head werden. Ausgabe 09/2018 ...
Seite 9
Observe the detailes for tolerances and variances (see page 10). At loss use another plastic/polymer foil with a thickness of 0.75 mm. Entfernen Sie die Abstandsfolie nach Festziehen der Montageschrauben. Remove the gap foil after tighten the mounting screws. Max. 1,2 Nm AK MS 45...
Montagemöglichkeiten / Mounting possibilities 6.1 MONTAGEMÖGLICHKEITEN AK MS 45 / MOUNTING POSSIBILITIES AK MS 45 6.2 MONTAGE AK ZU MAßSTABEINHEIT / MOUNTING AK TO SCALE UNIT 6.2.1 MS 45 MK 6.2.2 MS 45 MP = Kundenseitige Anschlussmaße / Required mating dimensions...
Connect the shield with the machine ground (field mass). Electrical short circuit! NOTICE The linear encoder is not protected against intrusion of intense contami- nation or water. Protect the linear encoder by applying a protective cover. AK MS 45...
Evaluation of counting signals via LED not active Steckerbelegung zu PWT 100 Funktionskontrolle Referenzimpuls RI Nur bei Überfahren der Referenzmarke Pinout adapter RSF Elektronik Function-control reference impulse RI Only by passing the reference mark standard connector pin assignment Anbau prüfen, Maßband reinigen RI ist außerhalb der Toleranz...
The linear encoders are not designed for self-modification or component replacement by the customer. Linear encoders from RSF Elektronik are designed for a long service life. Never open or modify the device yourself, as this will damage the device Preventive maintenance is not required.
Do not bend or deform scales or scale tapes excessively. Biegen / verformen Sie Maßstäbe bzw. Maßbänder nicht zu stark. Comply with the safety data sheets of solvents. Beachten Sie Sicherheitsdatenblätter von Lösungsmitteln. AK MS 45...
Observe the applicable country-specific regulations. Beachten Sie die Vorschriften des jeweiligen Landes. More detailed information on legal regulations can be obtained Genaue Informationen zu gesetzlichen Regelungen gibt from competent authorities. die zuständige Verwaltungsbehörde. AK MS 45...