1. Safety Guidelines

1. Follow the installation instructions.
2. Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3. Note that the appliance is exclusively for use in the
applications detailed in these installation instruc-
tions. Any other use will not be considered to comply
with requirements and would invalidate the
warranty.
4. Please take note that any assembly, commis-
sioning, servicing and adjustment work may only be
carried out by authorized persons.
5. Immediately rectify any malfunctions which may
influence safety.
• Make sure that the spring is released!
6. Make sure that the filter is neither exposed to to low
nor to high temperatures.
7. It is necessary during installation to observe codes
of good practice, to comply with local requirements
and to follow the installation instructions.

2. Functional description

Water flows through the filter mesh from outside to
inside and this traps dirt particles on the outer face of
the filter. For reasons of hygiene, the filter insert must
be replaced at no longer than six monthly intervals.
Activated Carbon cartridge filters out fine particles,
eliminates of unpleasant odours and flavours caused
by chlorine or other organic substances, removes of
pesticides, insecticides, chlorinate solvents.
Average life-span of activated carbon cartridges: about
6 months.

3. Application

Medium
Water

4. Technical data

Installation position
Horizontal with filter bowl down-
wards
Operating pressure
Maximum 6.0 bar
Operating temperatureMaximum 45 °C
Connection size
/
3
1" with
MU1H-1142GE23 R0608
" female,
4
/
"-1" adapter
3
4
GB

5. Scope of delivery

The filters comprise:
• Duplex or Simplex housing, wall bracket, wall
bracket screws
• Clear filter bowl
• Fine filter 25 µm,
• Activated Carbon insert
• ¾" female thread
• ¾"-1" Adapter
• Ring wrench for filter bowl

6. Options

FF40
Duplex water filter: mesh size 25µm
combined with activated carbon
FF20-MF Simplex water filter: mesh size 25µm
FF20-AC Simplex activated carbon

7. Assembly

7.1 Installations Guidelines
• Install in horizontal pipework with filter bowl down-
wards
o This position ensures optimum filter efficiency
• Fit shutoff valves before and after the filter
• Ensure good access
o Degree of contamination can be seen with clear
filter bowl
o Simplifies maintenance and inspection
• The installation location should be protected against
frost
• Do not install in places where there is strong
sunlight
7.2 Assembly instructions
1. Thoroughly flush pipework
2. Install filter
• Note flow direction (indicated by arrow)
o Install without tension or bending stresses
3. The appliance is ready for use