1.0 Technical data

Power suppley . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 V Batterie
Building moisture . . . . . . . . .Conversion according to material
Wood moisture . . . . . .4 - 100%, max. wood thickness 50 mm
Air humidity . . . . . . . . . . . . . . . . . . . . . . .7 - 95 % rel. humidity
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-10 - +35 ºC
Weight . . . . . . . . . . . . . . . . . . . . . . .400 g, without Accessories
Measurements: Plastic casing . . . . .L 180 x W 115 x H 53 mm

2.0 Safety Remarks

Warning:
The instructions for use of the meter and of the electrodes
should be carefully observed to avoid measuring errors which
may occur when trying to simplify the measuring procedure.
lt should be realized that a ris of injury exists by unprotected
measuring pins when carrying the meter around without
protective cap or any other safe guard.
A risk of injury also exists by careless handling of the measuring
pins while taking measurements.
Make sure with suitable means Prior to driving the pins into
walls, ceilings or floors that this will happen away from any
power line, water piping or other supply pipes.

3.0 Accessories for universal testers

Sensor B 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .#15882
For a non-destructive detection of building moisture.
Surface sensor OT 100 . . . . . . . . . . . . . . . . . . . . . . . . .#15889
For measuring the surface temperature.
Active electrode RFT 28 . . . . . . . . . . . . . . . . . . . . . . . .#15881
For a fast measurement of temperature and relative humidity.
Punch-in electrode M20, with 20 pins . . . . . . . . . . . . . .#13928
Push-in electrode M6, 2 pcs., with 6 pins . . . . . . . . . . .#15883
Contact material for push-in electrode M6
Measuring cable MK8 . . . . . . . . . . . . . . . . . . . . . . . . . .#13927
Steel pins for push-in electrode M6, 20 pcs.
23 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .#15885
40 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .#15886
60 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .#15888
Electrode, 2 pcs. M6 Bi200 (200mm) . . . . . . . . . . . . . . .#43606
Temperature sensor ET10..............................................#65603
. . . . . . . . . .#15884
15.11.2006Hydromette RTU 600
Hydromette RTU 600,
punch-in electrode M20,
measuring tips (steel pins),
2 push-in electrodes M6,
measuring cable MK8,
Push-in electrode M6
Sensor B50
Surface sensor OT100
Activ electrode RFT 28
Push-in electrode M 20
Contact material
Measuring cablel MK 8
Includes:
contact material,
sensor RFT 28,
carrying case