AS-I SONAR BERO
Operating Instructions
Application
The
is a position switch that operates without making
AS-I SONAR BERO
contact. It is for direct connection to AS-I, and is used to sense distances by
the echo delay-time method. It detects a sound-reflecting object which
enters the sound cone from any direction. The objects to be sensed can be
solid, liquid or in powder form.
The device has a temperature compensation feature.
Installation
Dimension drawing
see
Fig. I
any
Mounting position
Mutual interference
It is possible to acoustically couple two or more sensors of the same type
(spatial proximity), synchronization of the BEROs is recommended
(see
Fig. VI
).
Free space round sound cone axis
See
Fig. V
. Keep a clearance "x" (radius) round the sound cone axis free from
interfering objects.
for fixing thread: M30 max. 60 Nm
Tightening torque
Connection
With cable socket (M12) 3RX15.. (see
Pin assignment:
Pin No.
1
+
AS-I +
2
XI
enabling-/synchronization connection
3
-
AS-I -
The connections are
non-interchangeable
Operation
The temperature sensor (T) must be plugged in (see
Operating ranges 1 / 2 / 3
In the operating range, objects are sensed reliably within a sound cone
angle of 5° (cf.
). Under good reflection conditions, objects can also
Fig. IVa
be sensed outside.
Re.
:
Fig. IVa
a
Unusable blind zone
b
Sensing range
LED off: No object in operating range
LED on : Object in operating range
Blind zone
Blind zone "a" must be kept free from objects. Objects in the blind zone
generate undefined operating states.
Angular deviation of objects
Permissible angular deviation of the objects from the central vertical plane
(cf.
) at which safe operation is guaranteed:
Fig. Va
• In the case of smooth surfaces approx. 3°
• In the case of other surfaces, the permissible angular deviation is larger
and must -if necessary- be determined by experiment.
The swivel head is adjustable (see
Enabling
If enabling is blocked (XI), the switching state is stored in accordance with
the last measurement. On re-enabling, the output is updated after expiry of
the minimum enabling time t
.
Fr
(see
Enabling control by PLC
Fig. VII).
Maintenance
The unit is maintenance-free. The transformer surface, however, must not be
wetted, damaged, lacquered or covered with any material deposits.
2
.
(dimensions in mm)
M18 max. 20 Nm
Fig. III
)
View of BERO pins:
.
Fig. IVb
).
1
Operating range 1 (data bit D0)
2
Operating range 2 (data bit D1)
3
Operating range 3 (data bit D2)
.
Fig. II)
Order No.: 3ZX1012-0RG61-1AA1
Technical Data
Weight
Ambient temperature
Power supply:
Operating voltage AS-I +/-
No-load current
Mech. ambient conditions:
Vibrating stress
Shock stress
Degree of protection
EMC tests
To specification AS-I-Slave
Typ. values
SONAR BERO
Availability delay t
Reflection area [mm
for max. meas. dist.
Ultrasonic frequency
Measur. accuracy, resolution
Enabling input:
Min. enabling time t
Sensor active
1
Sensor not active
2
Synchronization:
3
By connection of pins XI max. 10
Setting parameters and operating ranges:
The BERO parameters and operating ranges can be set by the following
methods:
• With the programming and service unit (
• With the
PLC
• With the
PC
Data bits:
Data bit
D0
Operating range 1 active
D1
Operating range 2 active
D2
Operating range 3 active
D3
Alarm
Alarm output:
Failure of the transmitter or of the receiver, or substantial contamination of
the ultrasonic transducer are signalled to the control system via data bit D3.
The alarm signal does not guarantee 100% monitoring of the
SONAR BERO
NOT
be used for protection of persons or
functions.
For further details and accessories see Catalog NS3.
For further information on the AS-I
see the Actuator-Sensor Interface system description,
Order No.: E20001-P285-A497
.
approx. 150 g
-25 to +70°C
26,9 V to 33,6 V DC
< 75 mA
I
0
11 to 55 Hz, 1 mm amplitude
30 g, 18 ms
IP 65 except with separate transducer
IEC 801 Part 2-4 ≥ level 3
3RG61.2-. 3RG61.3-. 3RG61.4-. 3RG61.5-.
≤ 160 ms
≤ 180 ms
Start
2
]
10 x 10
20 x 20
400 kHz
200 kHz
1 mm
1mm
at XI
100 ms
110ms
Fr
Operating voltage of
high resistance
Input current I
0 to 3V
Input current I
BERO
(see
Fig. VI
PSG
function block
and the
SONPROG Software
Meaning
. Due to physical conditions,
3RG61..
English
≤ 380 ms
≤ 230 ms
100 x 100
50 x 50
80 kHz
120 kHz
2 mm
1 mm
400 ms
200 ms
SONAR BERO
or
max. 25 mA
E
max. -5 mA
E
).
)
s can
SONAR BERO

EMERGENCY-OFF