5

Operation

Danger
The dust extractor is not suitable
for extracting dusts that are
hazardous to health.

5.1 Switching on and off

Switch positions 1 (fig. 1)
0
=
Off
I
=
On (manual operation)
The volume flow display is switched over
to a fixed value which causes the signal
lamp to blink if the air speed drops below
20 m/s.
A
=
Stand-by mode for automatic switch on/off
function (dust extractor is switched on and
off by the electrical tool).
RA
=
Device designs with the equipment "RA"
can be operated as described under "A",
but in this case the vibrator is put into
operation for approx. 7 seconds for
automatic filter cleaning when the volume
flow display lights up and automatically
switches off afterwards.
The dust extractor S 50 / S 25 is equipped with an
electronic suction power control. The turning knob 2
can be used to adapt the suction power to the
material to be vacuumed.
The socket outlet 4 is provided for the connection of
an electrical tool (A/RA mode).
Danger
The electrical tool must be
switched off when it is connected.
When the power plug is plugged in,
the socket outlet is always live,
irrespective of the switch position.
In switch position "0", the socket
outlet can be used as extension
cord (e.g. for lamp).
Connected load: Dust extractor and
connected device max. 16 A.
To avoid excessive start-up peaks, the dust extractor
is equipped with a starting current limit (soft start).
Danger
While the dust extractor motor is
coasting down, the operating mode
selection switch may not be turned
until the dust extractor has come to
a standstill, otherwise the device
must afterwards be switched via
the 0-position to guarantee the
perfect functioning of the electronic
system.

5.2 Hints and information

- When vacuuming dry materials, the folded filter 5
(fig. 2) must be completely dry.
- During wet vacuuming, the built-in sensor prevents
the maximum filling level in the container from
being exceeded. The device no longer vacuums
when the container is full. Switch off motor. Pull the
dust extractor plug and empty the container.
- If the sensor responds when vacuuming larger
amounts of liquid (more than one container filling),
switch off the device and empty the container.
- If the volume flow display 3 (fig. 1) lights up on
restart, this may have the following reasons:
Container, filter bag 8 (fig. 4) full.
-
Extraction hose clogged.
-
Air cross sections of the dust generator too
-
small.
On completion of work, but especially if you do not
intend to use the device for a longer period of time,
you should:
- Discharge any dirt and liquids.
- Store the extraction hose such that there are no
kinks.
- Neatly reel up the mains cable and protect it
against damage.
6

Service and maintenance

Danger
Pull the power plug during all
service work.