3. Attach the Breakout cable's +24VDC (Red wire) and GND (Black wire) to
the corresponding terminals on the power supply.
CAUTION:
observe the polarity shown.
4. Connect the Breakout cable's M12 connector to the vision system's PWR
connector.
5. Restore power to the 24VDC power supply and turn it on if necessary.

Connect the Ethernet Cable

CAUTION:
The Ethernet cable shield must be grounded at the far end.
Whatever this cable is plugged into (typically a switch or router) should have a
grounded Ethernet connector. A digital voltmeter should be used to validate
the grounding. If the far end device is not grounded, a ground wire should be
added in compliance with local electrical codes.
1. Connect the Ethernet cable's M12 connector to the vision system's ENET
connector.
2. Connect the Ethernet cable's RJ-45 connector to a switch/router or PC, as
applicable.
Never connect voltages other than 24VDC. Always
13