Connect the External Light Cable (Optional)
The vision system's LIGHT connector is used to connect the External Light cable to
an external lighting device, providing power and strobe control. The External Light
cable can be connected to either a continuous or strobed lighting device.
1. Remove the protective cap from the LIGHT connector, if present.
2. Connect the External Light cable's M12 connector to the vision system's
LIGHT connector.
3. Connect the other end of the Light cable to an external lighting device (for
example, a strobe light).
Connect the Breakout Cable
CAUTION:
To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.
Note:
I/O wiring or adjustments to I/O devices should be performed when
l
the vision system is not receiving power.
Exposed wires can be cut short or wire ends trimmed, and the wires
l
tied back using a tie made of non-conductive material. Keep all bare
wires separated from the +24VDC wire.
1. Verify that the 24VDC power supply being used is unplugged and not
receiving power.
2. Optionally, connect the I/O wires to an appropriate device. 