WV36M/SSI
18
Accessory connector
NOTICE
7 Accessory connector
(not included in the scope of delivery)
7.1 Straight matting connector M12
Advice
` Strand cross sections of screened lines max. 0.5 mm² / cable feed-
through: ø6-ø8 mm.
• Accessory SIKO art. no. "83525" (socket contact 8 pin).
Mounting
(Fig.
1)
1. Mount seal to screen ring (4).
2. Slip parts 1 to 6 over outer cable.
3. Strip cable sheath, isolate conductor.
4. Shorten and turn down screen.
5. Clamp wires into socket (7) (follow connection diagram chapter 4.2).
6. Mount parts 2 ... 6. Place screen around screen ring (4).
7. Screw pressure screw (1) on coupling sleeve (5).
Fig. 1: Straight matting connector M12
WV36M/SSI · Date 24.08.2016 · Art. No. 85487 · Mod. status 203/16