Scope of delivery

2.6

Safety devices

 Pressure monitor: switches the compressor off if normal operating
pressure is exceeded.
 Pressure relief valves: additional safety mechanism to protect lines or
vessels from bursting if the pressure continues to rise despite the
safety pressure monitor.
 Fan and electronic box (delay circuit): checks the fans work properly
at start-up.
 Door opener contact prevents the front panel and dryer cover from
opening while operating.
3
Scope of delivery
The AirConServiceCenter and its accessories are carefully checked
before shipping.
After delivery, check that all the parts listed below are present and
undamaged.
If any parts are missing or damaged, notify the company responsible for
transport immediately.
Description
Adapter for 500 ml fresh oil and UV contrast agent bottle
Closed, patented drained oil receptacle
Sample bottle for professional oil can (Daphne Hermetic Oil), 100 ml
Sample bottle for UV contrast agent, 100 ml
Adapter for coolant bottles (large connection)
Protective unit cover
Goggles/gloves
Operating manual
A
NOTICE!
For safe operation and calibration, you require R-1234yf refrigerant (not
in scope of delivery).
Refrigerant vessels are currently supplied with various connecting
threads and adapters; these are not in the scope of delivery.