Herunterladen Diese Seite drucken
SystemAir AR series Bedienungsanleitung
SystemAir AR series Bedienungsanleitung

SystemAir AR series Bedienungsanleitung

Axialventilatoren

Werbung

Axialventilatoren
Inhaltsübersicht
Kapitel
Anwendung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Sicherheitshinweise. . . . . . . . . . . . . . . . . . . . . . . . . 1
Hinweis zur ErP-Richtlinie . . . . . . . . . . . . . . . . . . . . 2
Transport, Lagerung . . . . . . . . . . . . . . . . . . . . . . . . 2
Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Betriebsbedingungen . . . . . . . . . . . . . . . . . . . . . . . . 3
Inbetriebnahme. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Instandhaltung, Wartung, Reinigung . . . . . . . . . . . . . 4
Entsorgung / Recycling . . . . . . . . . . . . . . . . . . . . . . 5
Hersteller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Serviceadresse. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Anwendung

Systemair Axialventilatoren der Baureihen AR und AW
(Typenbezeichnung siehe Typenschild) mit integriertem
Außenläufer-Asynchronmotor sind keine gebrauchsfer-
tigen Produkte, sondern als Komponenten für Klima-, Be- und
Entlüftungsanlagen konzipiert. Eine spezielle Motorausle-
gung ermöglicht die Drehzahlsteuerung durch Spannungsab-
senkung. Bei Betrieb an Frequenzumrichtern beachten Sie
die Hinweise im Abschnitt Betriebsbedingungen.
Die Ventilatoren dürfen erst betrieben werden, wenn
sie ihrer Bestimmung entsprechend eingebaut sind
und die Sicherheit durch Schutzeinrichtungen nach
DIN EN ISO 13857 (DIN EN ISO 12100) oder sonstige
bauliche Schutzmaßnahmen sichergestellt ist.

Sicherheitshinweise

Die Ventilatoren sind zur Förderung von Luft oder luftähn-
lichen Gemischen bestimmt. Der Einsatz in explosionsge-
fährdeten Bereichen zur Förderung von Gas, Nebel,
Dämpfen oder deren Gemisch ist nicht zulässig. Die
Förderung von Feststoffen oder Feststoffanteilen im
Fördermedium ist ebenfalls nicht zulässig.
Montage, elektrischen Anschluss und Inbetriebnahme nur
von ausgebildetem Fachpersonal (Definition nach DIN EN
50 110, IEC 364) vornehmen lassen.
Gefahr durch elektrischen Strom! Der Rotor ist weder
schutzisoliert noch schutzgeerdet nach DIN EN 60204-1,
daher muss durch den Errichter der Anlage der Schutz
durch Hindernisse oder durch Anordnung außerhalb des
Handbereichs nach DIN VDE 0100-410 Anhang B vorge-
sehen werden, bevor der Motor an Spannung gelegt wird.
Betreiben Sie den Ventilator nur in den auf dem Typen-
schild angegebenen Bereichen und nur für die, laut Ihrer
Bestellung, bestimmungsgemäßen Anwendung.
Systemair Ventilatoren sind nicht dafür bestimmt, durch
Personen (einschließlich Kinder) mit eingeschränkten
physischen, sensorischen oder geistigen Fähigkeiten
benutzt zu werden.
Systemair Ventilatoren können, bei bestimmungsge-
mäßem Gebrauch, bis zu einer Umgebungstemperatur
von -40°C eingesetzt werden. Bei einem Einsatz unterhalb
-10°C und max. -40°C ist es Voraussetzung, dass keine
außergewöhnlichen äußeren Einwirkungen wie, stoßartige
mechanische Belastungen auf das Material einwirken. Bei
1~ Motoren mit Betriebskondensator bis -25°C. Beachten
Sie die maximale Umgebungstemperatur auf dem Typen-
schild.
Die max. zul. Betriebsdaten auf dem Typenschild gelten
für eine Luftdichte ρ = 1,2 kg/m
In die Wicklung eingebaute Temperaturwächter (TB) oder
Kaltleiter arbeiten als Motorschutz und müssen ange-
schlossen werden!
Seite
3
.
deutsch
Axial fans
Contents
Chapter
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . 1
Note on the ErP directive . . . . . . . . . . . . . . . . . . . . 2
Transport, storage . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . 3
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maintenance, repair, cleaning . . . . . . . . . . . . . . . . . . 4
Disposal / recycling . . . . . . . . . . . . . . . . . . . . . . . . . 5
Manufacturer: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Service address . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Application

Systemair axial fans of the series AR and AW (type desig-
nation see rating plate) with integrated external rotor
asynchronous motor are not ready-to-use products, but
designed as components for air-conditioning, air supply and
air extraction. A special motor design makes the speed
control by voltage reduction possible. By operation with
frequency inverters see the notes in the section Operating
Conditions.
The fans may only be operated when they are
installed as intended, and when safety is ensured by
safety equipment according to DIN EN ISO 13857
(DIN EN ISO 12100) or by other protection measures.

Safety instructions

The fans are intended for the transportation of air of
mixtures that are similar to air. Usage in potentially explo-
sive areas for the transportation of gas, mist, vapours or
their mixtures is not permissible. The transportation of
solid materials or similar materials in a transport media is
also not permissible.
Mounting, electrical connection and commissioning must
only be carried out by trained personnel (definition in DIN
EN 50 110 or IEC 364).
Danger of electrical current! The rotor is not protected by
insulation nor grounded to earth in accordance with DIN
EN 60204-1, and for this reason the system constructor
must provide protection in the form of obstacles or a loca-
tion outside the handling area in accordance with DIN VDE
0100-410, Attachment B, before the motor is connected to
a power source.
The fan is only to be operated within the ranges specified
on the type plate! Use the fan only in the authorised
fashion and only for the tasks and flow media specified in
the order!
Systemair fans are not designated for use by persons
(including children) of reduced physical, sensory and/or
mental abilities.
Systemair fans can be operated at ambient temperatures
down to -40°C when used properly. When used below -
10°C and max. -40°C it is a prerequisite that no unusual
external influences such as abrupt mechanical stresses
affect the material. For 1~ motors with a service capacitor
down to -25°C observe the maximum ambient temperature
stated on the type label.
The maximum permissible operating data given on the
rating plate are valid from air density ρ = 1.2 kg/m
The temperature monitors (TB) or PTC built into the
winding serve as the motor protection and must be
connected!
In models using PTC's, comply with the permissible test
voltage max. 2.5V!
english
1
Page
3
.

Werbung

loading

Inhaltszusammenfassung für SystemAir AR series

  • Seite 1: Inhaltsverzeichnis

    Service address ......5 Anwendung Application Systemair Axialventilatoren der Baureihen AR und AW Systemair axial fans of the series AR and AW (type desig- (Typenbezeichnung siehe Typenschild) mit integriertem nation see rating plate) with integrated external rotor Außenläufer-Asynchronmotor sind keine gebrauchsfer- asynchronous motor are not ready-to-use products, but tigen Produkte, sondern als Komponenten für Klima-, Be- und...
  • Seite 2: Hinweis Zur Erp-Richtlinie

    Hinweis zur ErP-Richtlinie Note on the ErP directive Die Fa. Systemair weist darauf hin, dass aufgrund der Verord- Systemair wishes to point out that, based on the directive nung (EU) Nr. 327/2011 der Kommission vom 30. März 2011 (EU) no.
  • Seite 3: Betriebsbedingungen

    – Bei vertikaler Motorachse muss das jeweils untenlie- – In the case of a vertical motor axis, the respective lower gende Kondenswasserloch geöffnet sein (gilt nicht bei condensation drain hole must be open (does not apply Ventilatoren der Schutzart IP55). to protection class IP55 fans).
  • Seite 4: Inbetriebnahme

    – Steuerung darf keine extremen Schaltbetriebe • Systemair Axial Fans are suitable for operation with zulassen! frequency inverters when the following points are • Systemair Axialventilatoren sind für den Betrieb an observed: Frequenzumrichtern geeignet, wenn folgende Punkte – Between the inverter and the motor, sinusoidal filters...
  • Seite 5: Entsorgung / Recycling

    Tel. +49 (0) 7930/9272-0 Phone +49 (0) 7930/9272-0 Fax +49 (0) 7930/9272-92 Fax +49 (0) 7930/9272-92 info@systemair.de info@systemair.de Serviceadresse Service address Länderspezifische Serviceadressen siehe Homepage unter For a list of our subsidiaries worldwide please refer to the www.systemair.de homepage at www.systemair.de deutsch english...
  • Seite 6: Eu-Konformitätserklärung Eu Declaration Of Conformity

    EU-Konformitätserklärung EU declaration of conformity Der Hersteller: Systemair GmbH The manufacturer: Seehöfer Str. 45 D-97944 Boxberg Tel.: +49 7930 9272-0 Produktbezeichnung: Axialventilatoren / Axial fans Product designation: Typenbezeichnung: AXC; AXC (K); AXC (B); AXC (F); AXC-G; AXC (B)-G; AXC-P; AXC (B)-P; AXS; AXC-E; AXC-EK;...

Diese Anleitung auch für:

Aw series