Use only System M18 chargers for charging System M18 battery
packs. Do not use battery packs from other systems.
SPECIFIED CONDITIONS OF USE
The drill stand is suited for drilling large holes in steel and other
ferroginous metals.

WORKING INSTRUCTIONS

The electromagnetic drill press attaches magnetically to 6,35 mm
or thicker ferrous stock. Do not use on stock less than 6,35 mm. The
magnetic base WILL NOT hold on nonmagnetic grades of stainless
steel.
The substrate under the drill stand has to be clean, rm, smooth,
dry, without polish and not have any holes in it.
Do not expose the drill stand to rain and do not use in damp or
non- ameproof rooms.
Keep constant pressure throughout the entire operation to prevent
chips and burrs from falling under the cutting edges. Cutting debris
under the cutter can make cutting di cult or impossible.
WARNING!
Excessive force will break magnet free.
Avoid contact with cutter tips. Periodically inspect the cutter tips
for loose or damaged tips.
The use of cutting uid is recommended for long life of these
cutters.
Secure the magnetic drill stand with the provided safety harness
when working slanting or vertical surfaces, or overhead such that it
won't fall down in case of power loss.
The safety harness must be applied such that the drill stand will
move away from the user in case of power loss.
Check safety belt for any damage and wear before every use. Do not
use defective safety belts!
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Do not remove cutter unless slug is removed. Slug may eject
unexpectedly.
AUTO STOP
AUTO-STOP switches the machine o automatically if there is a
too high, jerky operating torque on the magnet. Determine and
rectify the cause of the automatic stop by referring to the safety
information.
Possible causes can be:
• breakage of the material to be used
• excess load of the electric tool as a result of too high a feed rate
• unclean magnetic surface
Switch the machine o and then switch it back on again.
RESTART CUTOUT
If the machine is still switched on it will not restart after a power
failure. To restart it the machine must be switched o and then
on again.
MOTOR/MAGNET INTERLOCK
The motor/magnet interlock is a feature that prevents power from
being applied to the drill motor if the magnet is not energized.
The motor magnet interlock also prevents the magnet from being
de-energized while the motor is running.

EC DECLARATION OF CONFORMITY

We declare under our sole responsibility that the product described
under "Technical Data" ful lls all the relevant provisions of the
directives
2011/65/EU (RoHS)
2006/42/EC
2014/30/EU
and the following harmonized standards
EN 62841-1:2015
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:2015
EN 50581:2012
have been used.
Winnenden, 2018-05-28
Alexander Krug / Managing Director
Authorized to compile the technical le
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany
BATTERIES
Battery packs which have not been used for some time should be
recharged before use.
Temperatures in excess of 50°C (122°F) reduce the performance of
the battery pack. Avoid extended exposure to heat or sunshine (risk
of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum life-time, the battery packs have to be fully
charged, after use.
To obtain the longest possible battery life remove the battery pack
from the charger once it is fully charged.
For battery pack storage longer than 30 days: Store the battery
pack where the temperature is below 27°C and away from moisture
Store the battery packs in a 30% - 50% charged condition Every six
months of storage, charge the pack as normal.
Do not dispose of used battery packs in the household refuse or
by burning them. Milwaukee Distributors o er to retrieve old
batteries to protect our environment.
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Battery acid may leak from damaged batteries under extreme load
or extreme temperatures. In case of contact with battery acid wash
it o immediately with soap and water. In case of eye contact rinse
thoroughly for at least 10 minutes and immediately seek medical
attention.
BATTERY PACK PROTECTION
In extremely high torque, binding, stalling and short circuit situa-
tions that cause high current draw, the tool will vibrate for about 5
seconds, the fuel gauge will ash,and then the tool will turn OFF.
To reset, release the trigger. Under extreme circumstances, the
internal temperature of the battery pack could raise too much. If
GB
English