8. Setup and operation

If you have placed the outdoor unit and the indoor unit next to each other for test purposes and put them
into operation, please note that the microphone and speaker may produce loud feedback noises.
Such behaviour is normal.
Keep a distance of several metres between the outdoor unit and the indoor unit to avoid such feedback
noises during testing. Alternatively, temporarily apply several layers of duct tape on the microphone open-
ings.
Plug the included power adapter into a proper mains socket.
The "
" power LED (2) on the indoor unit will go on. The video door intercom system is then ready for use; it is in
standby mode.
If the LED does not go on, immediately unplug the power adapter from the mains socket and check the
wiring.

a) Visitor rings at the outdoor unit

• As soon as a visitor has pressed the bell button on the outdoor unit, the standby mode will end, the outdoor unit
camera will turn on and the white LEDs will go on. The camera image appears on the monitor of the indoor unit.
In addition, the speaker of the indoor unit will play a bell melody.
The bell melody will stop automatically in a few seconds; if you do not want to talk to the visitor, the image
on the indoor unit monitor will disappear in approx. 40 seconds. Finally, the video door intercom system
returns to the standby mode.
• Press the "
" button (10) to talk to the visitor. The "
The outdoor and indoor units will remain active for about 120 seconds before automatically returning to
standby mode.
• When the display of the outdoor unit camera shows the image, press the "
opener. The door opener will remain active as long as you keep the button pressed.
If you want to enable the second door opener, which opens the entrance gate, press the "
the door opener will remain active as long as you keep the button pressed. While enabling one of the two door
openers, the display goes out.
• If you want to end the call, press the "
go out. The video door intercom system returns to standby mode.
32
" red LED (3) will go on for control purposes.
" button (10). The display of the indoor unit and the "
" button (9) to enable the door
" button (7). Again,
" red LED (3) will

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis