E.2 - Procedure performed with an unmemorized transmitter
Before starting the procedure, bring the rolling shutter to the midpoint of its stroke.
01. Disconnect power supply from motor.
02. Connect the White and White-black wires to each other.
03. Disconnect power supply from motor.
04. Lastly, perform at the procedure indicated in paragraph E.1.
01
OFF
Note – During the procedure, you can abort the program at any time, by allowing 30 seconds to elapse between key presses.
F - Memorization of a SECOND transmitter (third, fourth, etc.)
Warning – To perform the procedure you must have a second transmitter ("old") already memorized.
Before starting the procedure, bring the rolling shutter to the midpoint of its stroke.
01. (on the new transmitter) Keep pressed the n key for 8 seconds and then release it (in this case the motor does not perform any movement).
02. (on the old transmitter) Give for 3 pulse to the n key, provided it has already been memorized.
03. (on the new transmitter) Give for 1 pulse to the n key to complete the procedure: the motor performs 3 movements. Attention! – If the motor performs 6 move-
ments, it means that its memory is full.
01
New
Note – During the procedure, you can abort the program at any time, by allowing 30 seconds to elapse between key presses.