66 | Installation
NOTICE
Bosch BPT-S 3 / 3.68 / 4 / 4.6 | Operating manual
Assembling the mains plug: Preparing the cables
and connecting the wires
(1)
5.6:
Individual components of the mains plug
[1]
Cable screw connection
[2]
Seal (3 different versions)
[3]
Housing
[4]
Contact carrier
Procedure
1. Strip the cable to 35 mm
Material damage due to damaged wire strands
Damaged wire strands can break and heat up to more
than 100 °C. This results in a risk of fire.
Do not damage the wire strands
2. Push the cable through the cable screw
connection
3. Select the correct seal for the cable diameter
4. Push the housing with the seal over the cable
5. Strip the wires to 12 mm (in the case of flexible
cables: Add and crimp an additional cable end
sleeve.)
(3)
(2)
English
(4)