Installation and User Manual HELO Roxx Premium
2.8 Locating the connecting box for the connection cable in the sauna room
A = Specified minimum safety clearance
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box
must be clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and
regulations of the local energy supplier.
2.9 LocatRemote controlling
The Heater can be remotely controlled by connecting a closed contactor, which can be pulse triggered, to connectors 3
and 4 of a RJ10 circuit board. The recommended cable size is AWG 24 or 26. The maximum length of an AWG 24 cable
is 200 m when using a Trend controller.
The maximum length of an AWG 26 cable is 130 m when using a Trend controller.
Kretskortet RJ kontakter
NOTE: Incorrect connections may break a circuit board.
Additional sensor (NTC)
Pin 1
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
Sensor (Sec/NTC)
Pin 1
End stop
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
End stop
A
3.
2.
Figure. 3 Location for the connection box
Pin layout of a RJ10 circuit board connector
Remote control switch (Ext switch)
Pin 1
3.3 V
Pin 2
CPU
Pin 3
To switch
Pin 4
To switch
Table 3 Coupling order of RJ 10
GND
connectors to circuit board
3.3 V
CPU
10V
A
3.
1.
2.
Pin 1
Pin 2
GND
Pin 3
12 VDC
Pin 4
Pin layout of a RJ10
connector
Door switch
Alarm LED
GND
Door
GND
switch
Door
12 VDC
switch
9