Timer - Mitsubishi Electric CITY MULTI PLFY-P.VBM-E serie Bedienungshandbuch

Air-conditioners for building application indoor unit
Vorschau ausblenden Andere Handbücher für CITY MULTI PLFY-P.VBM-E serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
3. Operation
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
MITSUBISHI ELECTRIC
LABEL
Manual vane angle
Select:
Outlet
Angle
F1
F2
F3
F4
Manual vane angle
Setting
Vane setting
No setting
Step 1
Step 2
Step 3
Step 4
Step 5
All outlets
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 4)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
the unit goes into operation.
Navigating through the screens
To go back to the Main menu ................ [MENU] button
To return to the previous screen .......... [RETURN] button

4. Timer

Timer functions are different by each remote controller.
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.
8
3 Select the "M-NET address" for
the units to whose vanes are
to be fixed, with the [F2] or [F3]
button, and press the [SELECT]
button.
Press the [F4] button to confirm
the unit.
The vane of only the target indoor
unit is pointing downward.
4 The current vane setting will
appear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] but-
ton.
4, (all outlets)"
Press the [F3] or [F4] button to go
through the option in the order of
"No setting (reset)," "Step 1", "Step
2", "Step 3", "Step 4" and "Step 5".
Select the desired setting.
will be displayed the next time
Con rmation procedure
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
M-NET address
The air conditioner with the
vane pointing downward is
the target air conditioner.
Input display:
F1
F2
F3
F4
Manual vane angle
There is no response from
the target device.
Confirm the state of the air
conditioner.
Input display:
F1
F2
F3
F4
Caution:
To prevent falls, maintain a stable footing when operating the unit.
3.6. Ventilation
For LOSSNAY combination
The following 2 patterns of operation is available.
1 Select the "M-NET address" for
the units to whose vanes are
to be fixed, with the [F2] or [F3]
button. Press the [F4] button to
2 After pressing the [F4] button,
wait approximately 15 seconds,
and then check the current state
of the air conditioner.
is displayed on the remote
controller.
Press the [RETURN] button and
continue the operation from the
beginning.
device does not exist at this
refrigerant address.
return to the initial screen.
3 Change the "M-NET address" to
the next number.
1 to change the
"M-NET address" and continue
with the confirmation.