Herunterladen Inhalt Inhalt Diese Seite drucken

Axis Q8665–LE Installationsanleitung Seite 39

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 79
CAUTION
• The electrical connections and conduit installations shall be made by a certified electrician
and in compliance with local regulations.
• Risk of fire. For continued protection against risk of fire, the fuses must be replaced
with the same type and rating.
1. Separate the pan/tilt unit from the base unit by removing the four screws, see section
Hardware Overview.
2. Check the fuses by using a multimeter. If the fuses are blown, change the fuses. See
the table below.
1
Pan/tilt unit
2
Base unit
3
Fuse F1
4
Fuse F2
Fuse Specification
Voltage
24/100 V AC 50/60 Hz
120 V AC 50/60 Hz
230 V A C 50/60 Hz
3. Attach the pan/tilt unit to the base unit.
AXIS Q8665–LE PTZ Network Camera
1
2
Fuse F1 5x20
F 6.3 A 250 V
F 6.3 A 250 V
F 6.3 A 250 V
39
3
4
Fuse F2 5x20
T 8 A 250 V
T 4 A 250 V
T 2 A 250 V