Herunterladen Inhalt Inhalt Diese Seite drucken

Type Plate; Motor Type Plate; Accessories - Helios SilentBox SB 125 A Montage- Und Betriebsvorschrift

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and Operating Instructions
Centrifugal Fan Boxes – SilentBox
Dimensions in mm
SBD 400
Ref. no. 9623
3.1

Type plate

Example:
e
y
o
d
Key for fan type plate:
– Manufacturer's address
— Fan label:
CE = CE mark
˜ Version:
SB
= type designation
250
= Size
™ Item number
š Production code / year of manuf.
The fan can be clearly identified by the ref. no., SNR (serial number) and PC (production code) numbers.

3.1.1 Motor type plate

Technical data about the motor can be found on the motor type plate!
3.2

Accessories

The use of accessories not offered or recommended by Helios is not permitted. Any potential damage is not covered
by warranty.
Flexible mounting clamp
Backdraught shutter
Outside wall cover flap
Outside wall cover grille
Protection guard
Vibration damper for tensile load
Vibration damper for pressure load
Electronic speed controller (recessed mounting)
Electronic speed controller (surface mounting)
Transformer speed controller 5-stage
Electronic speed controller for 3 fans
Transformer speed controller with motor protection device
Motor protection device for connecting
built-in thermal contacts
Flexible sound attenuator
Warm water heater battery
Temp. control system for warm water heater battery
Electric heater battery
-with integrated temp. control
Temp. control system for electric heating battery EHR-R..
Air filter cassette
Duct system:
All Helios components fit standard duct Ø. For example, rigid spiral ducts, flexible aluminium or plastic ducts can be
used. The relevant fire-protection regulations must be observed if more than two stories of a building are connected.
®
SB ...
Type
Type
SB 125 A 12 kg SB 315
SB 125 C 12 kg SBD 315 B 43 kg
SB 160 B 13 kg SBD 315 A 46 kg
SB 160 D 11 kg SB 355
SB 200 C 19 kg SBD 355
SB 200 D 20 kg SB 400
SB 250 C 35 kg SBD 400
SB 250 E 34 kg
q
w
r
t
u
i
s
f
› Nominal voltage / Frequency
œ Current in rated operation / Current in reg. operation
 Total input power
ž Nominal speed / Motor insulation class
Ÿ max. flow medium temp. at rated / regular operation
s Cosine
d Capacitor / protection class
f Installation and operating instructions/ Print no.
5
45 kg
47 kg
47 kg
61 kg
47 kg
Abb.3
FM..
RSKK / RSK
VK..
G / RAG..
SGR
SDZ
SDD
ESU..
ESA..
TSW / TSD
ESD
MWS/RDS..
MW / MD
FSD..
WHR
WHS HE.. / WHST..
EHR-R..
EHR-R.. TR
EHS
LFBR..
UK

Quicklinks ausblenden: