3. Operation
<Vane setting>
Fri
Swing
Off
Off
Vane
Vent.
Louver
F1
F2
F3
F4
Fri
Room
Cool
Set temp.
Auto
Mode
Temp.
Fan
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
<Returning to the Main menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
Press the [F1] or [F2] button to go
through the vane setting options:
"Auto", "Step 1", "Step 2", "Step 3",
"Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
lected angle.
under the vane setting icon
This icon will appear when the
vane is set to "Step 5" and the
fan operates at low speed during
cooling or dry operation (depends
on the model).
The icon will go off in an hour,
and the vane setting will auto-
matically change.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off
Low
High
Off
Low
door units may be interlocked
with certain models of ventilation
units.
Press the [RETURN] button to go
back to the Main menu.
<How to set the xed up/down air direction>
Note:
This function cannot be set depending on the outdoor unit to be
connected.
DOWN air direction setting of remote controller.)
Remote controller setting
The airflow direction of this
-
outlet is controlled by the airflow
direction setting of remote
controller.
Outlet No. 2
Outlet No. 1
Note:
The outlet No. is indicated by the number of grooves on both
ends of each air outlet. Set the air direction while checking the
information shown on the remote controller display.
High
-
Air outlet identification marks
Horizontal airflow
Fixed
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be
fixed horizontally to avoid direct airflow.
Outlet No. 3
Outlet No. 4