3. Operation
Manual vane angle (Wired remote controller)
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
Maintenance menu
Auto descending panel
Manual vane angle
3D i-See sensor
Main menu:
Cursor
F1
F2
F3
F4
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
Select:
Outlet
Angle
F1
F2
F3
F4
Manual vane angle
Setting
F1
F2
F3
F4
Note:
Do not set the draft reduction in an environment with high humidity.
Otherwise, condensation may form and drip.
10
1 Select "Maintenance" from the
Main menu (refer to page 8), and
press the [SELECT] button.
2 Select "Manual vane angle" with
the [F1] or [F2] button, and press
the [SELECT] button.
3 Select the "M-NET address" for
the units to whose vanes are
to be fixed, with the [F2] or [F3]
button, and press the [SELECT]
button.
Press the [F4] button to confirm
the unit.
The vane of only the target indoor
unit is pointing downward.
4 The current vane setting will
appear.
Select the desired outlets from
1 through 4 with the [F1] or [F2]
button.
3, 4, (all outlets)"
Press the [F3] or [F4] button to
go through the option in the order
of "No setting (reset)", "Step 1",
"Step 2", "Step 3", "Step 4", "Step
5" and "Draft reduction*".
Select the desired setting.
* Draft reduction
The airflow direction for this
setting is more horizontal than
the airflow direction for the "Step
1" setting in order to reduce a
drafty feeling. The draft reduction
can be set for only 1 vane.
Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All outlets
reduction*
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
the unit goes into operation.
Navigating through the screens
To go back to the Main menu ................ [MENU] button
To return to the previous screen .......... [RETURN] button
Con rmation procedure of the target unit
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
M-NET address
The air conditioner with the
vane pointing downward is
the target air conditioner.
Input display:
F1
F2
F3
F4
Manual vane angle
There is no response from
the target device.
Confirm the state of the air
conditioner.
Input display:
F1
F2
F3
F4
Step 2
Step 5
will be displayed the next time
1 Select the "M-NET address" for
the units to whose vanes are
to be fixed, with the [F2] or [F3]
button. Press the [F4] button to
2 After pressing the [F4] button,
wait approximately 15 seconds,
and then check the current state
of the air conditioner.
is displayed on the remote
controller.
Press the [RETURN] button and
continue the operation from the
beginning.
device does not exist at this
refrigerant address.
return to the initial screen.
3 Change the "M-NET address" to
the next number.
1 to change the
"M-NET address" and continue
with the confirmation.