5.1.2
Changing the ID/ baud rate via
the menu
1) Call up the submenu
2) The serial number is shown next to
this number again in the next line, next to
.
CONFIRM
3) Only when the two numbers are the same, it
will be possible to change the camera ID in
the line
and the
ID
(for remote control via RS-485) .
4) When the changes have been made, restart
the camera: At the control panel / recorder,
call up the command "Preset 94" or the
menu item
SYSTEM

5.2 Storage options

It is possible to save a great number of positions
in the camera; they can then be manually called
up by means of the control panel/recorder or
automatically started when the camera is re-
started or after an adjustable period of idling
(
  
  
SYSTEM
DEFAULTS
5.2.1
Presets
More than 100 camera positions, including
the zoom setting, can be saved as presets . The
control panels and PTZ control functions of the
recorders provide the appropriate commands to
save and call up these presets .
The following presets are designed to activate
specific command functions of the camera;
therefore, they are not available for normal
storage of positions .
Preset no. Function
62¹
to switch on IR LEDs (when IR ON / OFF = MANUAL)
63¹
to switch off IR LEDs (when IR ON / OFF = MANUAL)
92
to define the left limit for Scan 1
93
to define the right limit for Scan 1
94
to restart the camera, identical to menu item RESTART
95
to call up the OSD menu
97
to start Scan 1
98
to start Tour 1
99
to start Scan 1, identical to 97
101–116 ² to set the camera ID to ID 1– ID 16
9 ²
to call up the OSD menu, alternative to 95
¹ Available for storage of positions to be used in tours.
² This special function is only available while start-up information is
being shown
  
SYSTEM
ID SETTING
; enter
S/N
in the next line
BAUDRATE
  
  
DEFAULTS
RESTART
POWER UP RUN / IDLE RUN
5.2.2
Tour
The saved presets 1 – 80 can not only be called
.
up separately; it is also possible to combine them
to four tours and to go to them automatically .
For each preset of the tour, an individual transi-
tion speed and dwell time can be defined .
To program tours, use the menu item
  
TION
TOUR
  
FUNCTION
TOUR
use the command "IRIS +" or "IRIS −" . Further
options can be found in the menu table .
For a quick start of Tour 1, use the command
"Preset 98" .
.
5.2.3
Pattern
Any command movements, zoom commands
and focus commands can be saved in four pat-
terns .
Use the menu item
  
RECORD PATTERN
To terminate the recording, use the command
"IRIS +" . To reproduce a pattern, use the menu
) .
item
FUNCTION
cel the reproduction of a pattern at any time,
use the command "IRIS+" or "IRIS −" .
Further options can be found in the menu table .
5.2.4
Scan
Four scans provide the simplest way for sur-
veillance of a large zone . For these automatic
camera scans, only the right-hand and left-hand
limits of the zone to be scanned and the speed
must be defined .
To define the limits of a scan, use the menu
items
FUNCTION
save a defined limit, use the command "IRIS +" .
To define the speed, use the menu
  
  
SCAN
SCAN SPEED
found in the menu table .
To directly define the limits of Scan 1, use the
following commands: Presets 92 / 93 = left-hand /
right-hand limit .
For a quick start of Scan 1, use the command
"Preset 97" or "Preset 99" . To terminate a scan,
call up any other preset .
  
; to start a tour, use
EDIT TOUR
  
. To cancel a tour,
RUN TOUR
FUNCTION
to start recording a pattern .
  
  
PATTERNS
RUN PATTERN
  
  
SCAN
SET LEFT/RIGHT LIMIT
. Further options can be
FUNC-
  
PATTERNS
. To can-
. To
FUNCTION
17