Herunterladen Inhalt Inhalt Diese Seite drucken

Construction And Function; Construction; Function; Led Display - Balluff BTL6-V5_V-M_ _ _ _ -PF-S115 Serie Betriebsanleitung

Micropulse wegaufnehmer im profilgehäuse flach
Vorschau ausblenden Andere Handbücher für BTL6-V5_V-M_ _ _ _ -PF-S115 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL6-V5 _ V-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
3

Construction and function

Output signal rising
100% +10 mm
100%
0%
-10 mm
Error signal
Warning
signal
1)
13
63
10
~80
1) Unusable area
2) Not included in scope of delivery
Fig. 3-1:
BTL6... transducer, construction
3.1

Construction

Electrical connection: The electrical connection is made
via a connector (see Type code breakdown on page 14).
Housing: Aluminum housing containing the waveguide
and processing electronics.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories starting on
page 12).
Nominal length: To optimally adapt the transducer to the
application, nominal lengths from 50 mm to 4572 mm are
available.
3.2

Function

The BTL6 transducer contains the waveguide which is
protected by an aluminum housing. A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic speed.
6
english
Null point
1)
Nominal length =
Measuring range
2)
~250
Mounting clamps with insulating bushes
and ISO 4762 M5x25 cylinder head screws,
max. tightening torque 2 Nm
End point
Warning
Error signal
signal
1)
1)
10
63
~250
~80
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is conver-
ted by a coil into an electrical signal. The travel time of the
wave is used to calculate the position.
This information is transferred via the VARAN interface.
VARAN is an industrial bus system based on the physical
layer of the Ethernet (see www.varan-bus.net).
3.3

LED display

In normal operation the LED indicates the
operating states of the VARAN bus.
LED
Operating state
Green
Ethernet Connection available
Orange
Data is being transmitted via the VARAN bus.
Tab. 3-1:
LED display
BTL5-P-3800-2 magnet
2)
LED
34.8
50
68

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis