Floating magnets

The following must be observed when installing the
magnet:
To ensure the accuracy of the position measuring
system, the magnet is attached to the moving member
of the machine using non-magnetizable screws
(stainless steel, brass, aluminum).
The moving member must guide the magnet on a track
parallel to the transducer.
Ensure that the distance A between the magnets and
parts made of magnetizable material is at least 10 mm
(see Fig. 4-4 to Fig. 4-8).
Maintain the following values for distance B between
the magnet and transducer and for center offset C (see
Fig. 4-4 to Fig. 4-8):
Type of magnet
BTL5-P-3800-2
BTL5-P-5500-2
BTL5-P-4500-1
BTL6-A-3800-2
BTL6-A-3801-2
The selected distance should stay constant over the entire measuring
1)
length.
For optimum measurement results, a distance B of 6 to 8 mm is
2)
recommended.
Tab. 4-1:
Distance and offset for magnets (see Fig. 4-4 to Fig. 4-8)
A
A
Fig. 4-4:
Dimensions and distances with BTL5-P-3800-2 magnet
A
A
Fig. 4-5:
Dimensions and distances with BTL5-P-5500-2 magnet
8
english
Distance B
Offset C
1)
0.1...4 mm
± 2 mm
5...15 mm
± 15 mm
0.1...2 mm
± 2 mm
4...8 mm
± 5 mm
2)
4...8 mm
± 5 mm
2)
C
C
A
A
Fig. 4-6:
Dimensions and distances with BTL6-A-3800-2 magnet
A
A
Fig. 4-7:
Dimensions and distances with BTL6-A-3801-2 magnet
Plug with
A
A
LED
4
Fig. 4-8:
Dimensions and distances with BTL5-P-4500-1
electromagnet (24 V/100 mA)
BTL5-P-4500-1:
The measuring range is offset by 4 mm towards
the transducer plug (see Fig. 4-8).
C