SAFETY INSTRUCTIONS

CURRENT PROBE
ITEM NO.: 1693351 VC-522 AC
ITEM NO.: 1693352 VC-523 AC/DC
ITEM NO.: 1693353 VC-532 AC
ITEM NO.: 1693354 VC-533 AC/DC
The accompanying CD contains detailed and multi-lingual operating
instructions.
Read the operating instructions before using the product.
Up-to-date Operating Instructions:
1. Open www.conrad.com/downloads in a browser or scan the displayed
QR code.
2. Select document type and language and enter the item number into
the search field. After submitting the query you can download displayed
records.
In these safety instructions you will find the phrase "Technical product
documentation" This includes the following:
• These safety instructions
• The manual for the corresponding product
• Other safety and operation-related documentation (where applicable)
SIGNS AND SYMBOLS
The triangle containing an exclamation mark indicates important information
in the product documentation that must be observed.
The triangle containing a lightning symbol warns against danger of electric
shock or impairment of the electrical safety of the device.
This product conforms to CE standards and complies with the necessary
European directives.
Protection class 2 (double or reinforced insulation, protective insulation)
Measurement category I (overvoltage category) for measurements on
electrical and electronic devices that are not directly connected to the mains
CAT I
(e.g. battery-operated devices, protective extra-low voltage, signal and
control voltages etc.).
Measurement category II (overvoltage category) for measurements on
electrical and electronic devices that are directly connected to the mains
CAT II
voltage via a mains plug. This category also includes all lower categories
(e.g. CAT I for measuring signal and control voltages).
Measurement category III (overvoltage category) for measurements in building
installations (e.g. power outlets and sub-distribution units). This category also
CAT III
includes all lower categories (e.g. CAT II for measuring electrical devices).
Measuring in CAT III is only permitted with test prods with a maximum free
contact length of 4 mm or with cover caps over the test prods.
Measurement category IV (overvoltage category) for measurements at the
source of a low-voltage installation (e.g. main distribution board, house
delivery point of energy provider etc.) and outdoors (e.g. working on
CAT IV
underground cables or overhead lines etc.). This category also includes all
smaller categories. Measuring in CAT IV is only permitted with test prods with
a maximum free contact length of 4 mm or with cover caps over the test prods.
The square containing the lightning symbol warns against dangerous, active
conductors. This means that you can take measurements on insulated and
uninsulated conductors using the current transformer. The markings on the
handle must not be gripped when taking measurements!
Earth potential
SAFETY INSTRUCTIONS
Read the technical product documentation carefully and especially
observe the safety instructions.
If you do not follow the safety instructions and information on proper
handling in the technical product documentation, we assume no liability
for any resulting personal injury or damage to property. Such cases will
invalidate the warranty/guarantee.
VERSION 07/18
The measuring device must only be used by people who are familiar
with the necessary provisions for measurements and the possible
hazards. The use of personal protective equipment is recommended.
Consult an expert when in doubt about the operation, safety or
connection of the device.
a) People
• Make this product available to third parties only together with the technical product
documentation. Store this documentation in a safe place.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. This may become dangerous
playing material for children.
• Pay attention to the necessary safety information, regulations and protective measures for
your own safety.
b) Product
• The product was shipped in a safe and secure technical condition. To ensure that the
product remains safe to use, the user must observe the safety instructions and warnings
that come with the product.
• For safety and approval purposes, you must not rebuild and/or modify this product. If
you use the product for purposes other than those described above, the product may be
damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric
shock etc.
• This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
c) Environmental conditions
• Do not place the product under any mechanical stress.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height can
damage the product.
• Unsuitable environmental conditions include:
- Extreme temperatures
- Direct sunlight
- Strong vibrations
- Moisture or high humidity
- Dust and flammable gases, vapours or solvents.
- Storms or other similar conditions, e.g. strong electrostatic fields.
- Measurements must not be made in potentially explosive areas, damp rooms or in
adverse environmental conditions.
Important! If the product is designed to be used in one or more of the aforementioned
environments, this will be indicated in the operating instructions.
• Avoid using the device in the immediate vicinity of:
- Strong magnetic or electromagnetic fields
- Transmitting antennas or HF generators
• Do not use the product shortly before, during or shortly after a storm (lightning/powerful
overvoltages!).
• If it is no longer possible to operate the product safely, take it out of operation and protect it
from any accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or has been exposed to
considerable transport-related stress.
d) Accessories
• For safety reasons, only use measuring cables (and other accessories) that conform to the
product specifications.
• Before measuring, check the connected measuring cables or connected accessories for
damage such as cracks or breaks.
• Damaged measuring cables (and other accessories) must not be used and constitute a
fatal hazard! If any measuring cables (or other accessories) are damaged, discontinue use
and prevent them from being used unintentionally.