Herunterladen Inhalt Inhalt Diese Seite drucken

General Safety; Electrical Connection; Air Vent; English - Indesit H 461 IX.1 Betriebsanleitung

Inhaltsverzeichnis

Werbung

English

The hood can look different to that illustrated in the drawings in this
EN
booklet. The instructions for use, maintenance and installation, however,
remain the same.
Closely follow the instructions set out in this manual. All responsibility, for
any eventual inconveniences, damages or fires caused by not complying with the
instructions in this manual, is declined. The hood is conceived for the suction of
cooking fumes and steam and is destined only for domestic use.
!
It is important to conserve this booklet for consultation at any moment. In
the case of sale, cession or move, make sure it is together with the product.
!
Read the instructions carefully: there is important information about
installation, use and safety.
!
Do not carry out electrical or mechanical variations on the product or on the
discharge conduits.
!
Before proceeding with the installation of the appliance verify that there are
no damaged all components. Otherwise contact your dealer and do not
proceed with the installation.

GENERAL SAFETY

The minimum distance between the supporting surface for the cooking
equipment on the hob and the lowest part of the range hood must be not less
than 50cm from electric cookers and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this
must be adhered to.
Expansion wall plugs are provided to secure the hood to most types of
walls/ceilings. However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling. The wall/ceiling must be
strong enough to take the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Before any cleaning or maintenance operation, disconnect hood from the mains
by removing the plug or disconnecting the mains electrical supply.
Always wear work gloves for all installation and maintenance operations.
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not be allowed to tamper with the controls or play with the
appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
The premises where the appliance is installed must be sufficiently ventilated,
when the kitchen hood is used together with other gas combustion devices or
other fuels.
The hood must be regularly cleaned on both the inside and outside (AT LEAST
ONCE A MONTH).
This must be completed in accordance with the maintenance instructions
provided in this manual. Failure to follow the instructions provided in this user
guide regarding the cleaning of the hood and filters will lead to the risk of fires.
The flaming of foods beneath the hood itself is severely prohibited.
The use of exposed flames is detrimental to the filters and may cause a fire risk,
and must therefore be avoided in all circumstances.
Any frying must be done with care in order to make sure that the oil does not
overheat and ignite.
CAUTION! Accessible parts of the hood may become hot when used with
cooking appliance.
For
lamp
replacement
Maintenance/Replacing lamps section of this manual.
WARNING! Do not connect the appliance to the mains until the installation is
fully complete.
With regards to the technical and safety measures to be adopted for fume
discharging it is important to closely follow the regulations provided by the local
authorities.
The ducting system for this appliance must not be connected to any existing
ventilation system which is being used for any other purpose such as discharging
exhaust fumes from appliances burning gas or other fuels.
Do not use or leave the hood without the lamp correctly mounted due to the
possible risk of electric shocks.
Never use the hood without effectively mounted grids.
The hood must NEVER be used as a support surface unless specifically
indicated.
Use only the fixing screws supplied with the product for installation or, if not
supplied, purchase the correct screws type.
14
use
only
lamp
type
indicated
Use the correct length for the screws which are identified in the Installation
Guide.
In case of doubt, consult an authorised service assistance centre or similar
qualified person.
WARNING! Failure to install the screws or fixing device in accordance with these
instructions may result in electrical hazards.
We will not accept any responsibility for any faults, damage or fires caused to the
appliance as a result of the non-observance of the instructions included in this
manual.

ELECTRICAL CONNECTION

The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket in
compliance with current regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection) or if the plug is not
located in an accessible area, after installation, apply a double pole switch in
accordance with standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in accordance with
installation instructions.
Warning! Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains cable is correctly
assembled.
Replacing the power cable
Warning! Power cable replacement must be undertaken by the authorised
service assistance centre or similar qualified person.

AIR VENT

(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent to
the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause
a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct as smooth as possible inside.
!
The duct must be made of certified material.
!
The company declines any responsibility whenever these regulations are
not respected.
FILTERING OR DUCTING ?
!
Your cooker hood is ready to be used in suction version.
To use the hood in filtering version the special ACCESSORY KIT must be
installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished
or must be bought separately.
Note: If furnished, in certain cases, the additional activated carbon filtering
system may be installed on the hood.
Information about the conversion of the hood from suction version to filtering
version is present in this manual.
Ducting version
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
Attention! The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
in
the
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°)
and directed upwards to vent the air easily from the room to the outside.
Attention! If the hood is supplied with active charcoal filter, then it must be
removed.
Filter version
The aspirated air will be degreased and deodorised before being fed back into
the room.
In order to use the hood in this version, you have to install a system of additional
filtering based on activated charcoal.
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis