Operation
WARNING
the cord to come into contact
with the rotating brushes.
1) Using a hose or bucket, fill the solution
tank with hot water. (max. 120°F/50°C,
capacity 9 Gal./35L).
2) Add distributor recommended detergent.
3) Connect the supplied extension power
cable to the machine. Plug cord into a
grounded wall outlet.
4) Turn on power switch and vacuum /
pump switch.
5) To start cleaning, press the spray mode
switch and begin to pull the machine
backwards. (Note: appliance will only spray
when the pump switch is ON and the spray
mode switch is pressed.)
6) Release spray button at the end of the
path and continue to pull machine back to
pick up excess solution.
7) Tip machine back onto the transport
wheels and push forward to begin next path.
Cleaning tips:
1) Run across the surface to be cleaned in
overlapping paths.
2) Let the detergent solution soak for 5 to
10 minutes on heavily soiled areas and
repeat cleaning several times.
3) Work away from power outlet and power
cable in order to avoid damage to the power
cable.
4) Continually check for foam buildup in
recovery tank. Use a distributor
recommended foam control solution. (Note:
Excessive foam buildup will not activate the
float shut-off and may cause damage to the
vacuum motor.)
5) If the brush stops spinning, there may be
an obstruction in the brush. Unplug the
power cable , check the brush and remove
the obstruction.
6) When recover tank is full, or the solution
tank is empty, you must drain the recovery
tank. (refer to draining reservoir)
: Do not allow
12
Operation with accessory tools (Only
recommended/authorized parts and
accessories should be used).
An optional accessory hand tool can be
attached to clean upholstery and stairs.
Operation with hand tool (refer to F7):
1) Disconnect the normal vacuum hose out
of the dome.
2) Insert the accessory vacuum hose into
the dome instead of the normal vacuum
hose.
3) Connect the accessory quick connector to
the quick coupler located on the back of the
machine.
4) Turn on power switch and vacuum
motor/ water pump switch.
5) Use the lever on the hand tool to spray
on detergent solution.
6) When cleaning is completed, turn off
water pump /vacuum motor switch and then
squeeze trigger 3 seconds to relieve water
pressure from solution lines.
Shutting down
1) Turn off machine, unplug and remove
power cable.
2) Empty the recovery tank and solution
tank. (refer to Draining tanks)
Draining tanks
Draining recovery tank (refer to F8):
1) Move the machine to an appropriate
draining location. (Please consider the
environment)
2) Hold the drain hose for the recovery tank
and lower it over the drain. Open the drain
hose cover for recovery tank draining.
3) Replace the drain hose back onto
machine.
Draining solution tank (refer to F9):
1) Move the machine to an appropriate
draining location. (Please consider the
environment)
2) Disconnect the hose coupling and lower
the hose for solution tank draining.
3) Connect the hose coupling back onto the
machine.
Machine maintenance