Control / Visualisation
If cleaning is not currently possible, an additional day (+1) can be requested once.
The display flashes, alternating between red and white.
Fig. 29: Alarm level - Deactivation 'Beer Cut'
The 'Beer Cut' is disabled. The display flashes, alternating between yellow and green.
Fig. 30: Alarm level - Activation 'Beer Cut'
At the end of the additional day, the 'Beer Cut' is reactivated. Cleaning must be carried
out. The display flashes, alternating between red and white.
4.5.4

Alarm - Temperature

Fig. 31: Alarm level - Temperature switch
Temperature switch:
If the temperature in the unit rises above 65 °C, the compressor is switched off and a
warning symbol and thermometer symbol are shown in the display.
The compressor is switched back on again when the temperature falls back down to
below 50 °C.