Herunterladen Inhalt Inhalt Diese Seite drucken

Startup; Starting Up The System; Operating Notes - Balluff BAW M12MI-BLC35C-S04G Betriebsanleitung

Induktiver abstandssensor
Vorschau ausblenden Andere Handbücher für BAW M12MI-BLC35C-S04G:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BAW M12MI-BLC35C-S04G and BAW M12MH-BLC70G-S04G
Inductive Linear Position Sensor
5

Startup

5.1

Starting up the system

DANGER
Uncontrolled system movement
When starting up, if the distance measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the sensor, if necessary.
Check for the correct values at the null point
and end point, especially after replacing the
sensor or after repair by the manufacturer.
5.2

Operating notes

Check the function of the positioning system and all
associated components on a regular basis.
Take the positioning system out of operation whenever
there is a malfunction.
Secure the system against unauthorized use.
8
english

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Baw m12mh-blc70g-s04g

Inhaltsverzeichnis