6
IO-Link interface (continued)
6.4

Identification parameters

Index
Parameters
Hex. Dec.
0010 16
Vendor name
0011 17
Vendor text
0012 18
Product name
0013 19
Product ID
0014 20
Product text
0016 22
Hardware revision
0017 23
Firmware revision
0018 24
Application specific tag
Tab. 6-4:
IO-Link identification data
Access to subindex 0 addresses the entire
object of an index. Access of subindices >0
addresses the individual elements of an index.
Device Access Locks
With this standard parameter, it is possible to active or
deactivate certain functions of the IO-Link device. With
BAW M12M_-BLC_ _ _-S04G, there is the option to lock
the function of the parameter manager. To do so, bit 1 of
the 2-byte value must be set to "1" (locked). In order to
unlock the parameter manager, bit 1 is set to "0".
Bit
Function
0
Parameter access
1
Parameter management
2
Local parameterization
3
Local user interface
4...15 Reserved
Tab. 6-5:
Lock parameter data
www.balluff.com
Data format (length)
StringT (7 bytes)
StringT (15 bytes)
StringT (21 bytes)
StringT (7 bytes)
StringT (28 bytes)
StringT (3 bytes)
StringT (8 bytes)
StringT (max. 32 bytes)
Lock
Supported
Not
supported
X
X
X
X
Access
Contents
Read only
"BALLUFF"
Read only
"www.balluff.com"
Read only
"BAW M12MI-BLC35C-S04G"
Read only
"BAW004M"
Read only
"Inductive Positioning System"
Read only
"XX"
Read only
"vX.XX.XXX"
Read/Write
***
Profile Characteristic
This parameter indicates which profile is supported by the
IO-Link device.
The inductive linear position sensor
BAW M12M_-BLC_ _ _-S04G supports the Smart Sensor
Profile with a process data variable:
Subindex 1 ("Profile Identifier -> DeviceProfileID"):
0x0001 ("Smart Sensor Profile")
Subindex 2 ("Profile Identifier -> FunctionClassID"):
0x8000 ("Device Identification Objects")
Subindex 3 ("Profile Identifier -> FunctionClassID"):
0x8002 ("ProcessDataVariable")
PD Input Descriptor
This parameter describes the composition of the process
data variables used.
The inductive linear position sensor
BAW M12M_-BLC_ _ _-S04G processes the process data
variables (see Tab. 6-6 on page 12).
Application Specific Tag
The Application Specific Tag makes it possible to assign
the IO-Link device an arbitrary, 32-byte string. This can
only be used for application-specific identification and
applied in the parameter manager. The entire object is
accessed via subindex 0.
english
11