Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Warning; Maintenance - Vitavia ORION 3800 Montageanleitung

Vorschau ausblenden Andere Handbücher für ORION 3800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
EN
1. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE ASSEMBLING YOUR GREENHOUSE.
2. Sharp edges and corners can cause injury. Always wear protective glasses, gloves, shoes and headgear when handling the aluminium profiles, glass and
polycarbonate sheets. Broken glass is a safety hazard – always clear up immediately and dispose of with care.
The product you have purchased is intended only for growing plants
3.
responsibility.
4. It is recommended that this greenhouse is assembled by two people.
5. Should you encounter difficulties constructing this house, or in fitting the glass or polycarbonate sheets, please contact your retailer
– do not use force!
6. The greenhouse must always be anchored.
SIte SelectIoN
Always try to select a sunny location, sheltered
from the wind as much as possible.
ImPoRtaNt
Before assembling your new greenhouse,
please check that all parts in the provided list
are included. Please take each bundle out of
the packaging in order to identify the parts
better.
It is important that the opened bundles do not
get mixed with one another.
If something is missing please contact your
retailer.
Nuts (1002) - max. tightening torque 3Nm.
NeceSSaRy toolS
Screw drivers (Normal and Crosshead PH2),
10 mm socket spanner or wrench, 10 mm
combination spanner, knife, measuring stick,
spirit level, Accu-drill with adjustable torque.

maINteNaNce

The greenhouse should be thoroughly washed
with a gentle detergent occasionally. Please
check that the detergent used does not react
aggressively with aluminium or the glass fixing
clips.
Ensure that the upper and lower door tracks
are cleaned regularly to avoid a build up of
debris.
0. BaSe
Important! The base must be exactly square
and level. A zinc-coated steel base is available
as an accessory for all greenhouse models.
(attention! Only when the greenhouse has to
be located in a very windy and unprotected
location: Drill through both the profile at the
base of the greenhouse and the steel base,
and connect them with nuts and bolts.)
If you would rather construct your own stone
4

Safety Warning

and should only be used for this purpose. When used for other purposes we will take no
Assembly Instructions
or concrete foundation, please follow the
dimensions specified in diagram 0. Treated
wooden beams at least 18 mm high and not
more then 32 mm wide should be positioned
between the stone/concrete foundation and
the aluminium frame, and connected to the
foundation with 50 mm long bolts (not pro-
vided).
Foundations must extend down below the frost
level.
Diagrams in a single frame show the view
from inside the greenhouse. those enclo-
sed in a double frame show the view from
outside the greenhouse.
1. SIDe elemeNtS
Lay all of the parts on the floor and connect
them loosely.
For Orion 5000 – It is necessary with each
outside vertical aluminium bar (1032) to include
an extra connecting bolt at this stage. This bolt
is required to connect the cross braces (5595),
see (1.2).
Loosely connect the corner plate (5091) (1.1).
In step 4 the corner plate bolts must also be
connected to the gable ends.
2. PlaIN GaBle eND
Lay all of the parts on the floor and connect
them loosely.
Include one extra connecting bolt in the
vertical bars (5041) and (5042) to connect the
cross braces (2.2).
3. DooR GaBle eND
Lay all of the parts on the floor and connect
them loosely.
The door runner bars (5547) will be connected
to the horizontal bar (5548). Connect these
loosely from the outside with two nuts and
bolts.
Depending on which direction the door should
open, align door runner bar ( 5547) to the left
or to the right.
Connect the parts (5001) and (5002) as shown
in (3.4) & (3.5) with a bolt.
Please include one extra bolt in the vertical
bars (5041) and (5042).
4a. coNNectING the SePaRate
elemeNtS
Bolt the side elements to the end elements.
(4.1), (4.2) & (4.2)
Assemble the ridge bar on the gable ends
(4.4).
Connect the door runner supports (5043) to
the door runner bars (5547) and to the gable
end, using bolt (1005) and spacer (1010) (4.5).
Connect the door runner supports (5043) to
the door runner bars (5547) and to the gabel
end, using washer (6060), bolt (1005) and
spacer (1010) (4.5).
4B. coNNectING the SePaRate
elemeNtS
Connect the roof glazing bars (5555) between
the eaves (4.6) and the ridge bar (4.7).
Insert extra bolts into each glazing bar depen-
ding on which house you have bought. The
number is indicated in a circle on each bar and
to be read beginning from both ends.
The roof braces (3057) (4.8) and the cross
braces (5540) (4.10) & (4.11) can now be con-
nected.
Now position your greenhouse on the
prepared base / foundation and connect
loosely. Adjust the greenhouse until it is com-
pletely square and tighten all bolts.
Please do not over tighten. (max. 3Nm)
Press the end protectors (1017) onto the eave
008.01.1411

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Orion 5000

Inhaltsverzeichnis