Getting Started

The ceiling alarm is operational immediately after inserting the batteries and installation.
With the "ARM/DISARM" button, you can turn the ceiling alarm on and off. For this purpose, point the reddish/
transparent front of the IR remote control at the red plastic cover on the ceiling alarm.
The IR remote control functions up to a 30° angle to the IR receiver in the ceiling alarm, with a maximum
distance of approx. 6 m.
Stand-by
• red LED off
• green LED off
Arming phase
• red LED off
• green LED on
• one beep
Alert mode
• red LED fl ashes
• green LED off
45 seconds
Alarm delay, 15s
• red LED fl ashes
• green LED off
Alarm tone activated, 45s
• red LED fl ashes
• green LED off
• Alarm tone is activated
for 45 seconds and stops
automatically afterwards
• After an pause of 45
seconds, the ceiling alarm
is re-armed
Standby (idle mode):
If you insert batteries into the ceiling alarm or connect it to an external power supply unit, the ceiling alarm
switches to standby mode. Here, neither of the two LEDs fl ash.
A red LED lights up behind the transparent PIR sensor lens, when the ceiling alarm detects a temperature
change in the detection area. This function can be used to monitor the detection area of the PIR motion
detector.
The ceiling alarm can be turned on using the IR remote control.
Arming phase:
When the ceiling alarm is in standby mode, briefl y press the "ARM/DISARM" button on the IR remote control
once. The ceiling alarm switches to the so-called arming phase. You will hear a short beep and the green
LED will light up for approx. 30 seconds. While in the arming phase, you can reset the ceiling alarm back to
standby mode by pressing the "ARM/DISARM" button.
If the arming phase is not cancelled, the ceiling alarm is armed after 30 seconds. It is now in alarm mode.
For this reason, you have to leave the detection area within these 30 seconds, otherwise you will
trigger the alarm.
Alert mode:
After an arming phase of 30 seconds, the ceiling alarm switches automatically to the alert mode. The green
LED goes out and the red LED starts to fl ash. The ceiling alarm is now armed and monitors any temperature
changes in the PIR motion detector's detection area.
Alarm delay:
If the ceiling alarm is armed (red LED fl ashes), and someone enters the detection area, the alarm delay is
triggered, which lasts for 15 seconds (no alarm tone is emitted yet).
If you press the "ARM/DISARM" button on the IR remote control within these 15 seconds (point the front of
the IR remote control at the ceiling alarm!), the alarm will be switched off and returned to the standby mode.
Thus, you have 15 seconds to deactivate the ceiling alarm when you enter your apartment before the alarm
tone is triggered.
Alarm tone activated:
If someone enters the detection area without authorisation (the ceiling alarm is not deactivated using the IR
remote control), the alarm tone is activated after 15 seconds, and it will last for 45 seconds, if a temperature
change is detected in the detection area.
After this, the alarm tone is switched off automatically. After 45 seconds waiting time, the ceiling alarm is
armed once again and can trigger a new alarm, if a temperature change is detected in the PIR motion detec-
tor's detection area.
Testing the detection area
• Set the ceiling alarm to the standby mode (none of the LEDs fl ash, ceiling alarm turned off).
• Move into the PIR detection detector's detection area.
• If a temperature change is detected, a red LED lights up behind the transparent PIR sensor lens. You may
have to darken the room a bit, so that you can see the LED better.

Maintenance and Cleaning

Apart from the the occasional battery change, the product is maintenance-free.
Repair or maintenance work must be carried out by a specialist.
Clean the product with a soft, clean, dry cloth.
Press once briefl y
Never use aggressive cleaning agents or chemical solutions since these might damage the surface of the
casing or impair the operation.
Disposal
a) In general
30 seconds delay to
leave the detection area
Dispose of an unserviceable product in accordance with the relevant statutory regulations.
Remove any rechargeable batteries inserted and dispose of them separately from the product.
b) Disposal of used batteries/rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all used batteries/rechargeable bat-
teries; disposal of them in the household waste is prohibited!
Contaminated batteries/rechargeable batteries are labelled with these symbols to indicate that
Motion is detected
disposal in the domestic waste is forbidden. The symbols for the relevant heavy metals are: Cd
= Cadmium, Hg = Mercury, Pb = Lead.
Press briefl y
You can dispose of your used batteries/rechargeable batteries free of charge at your community's collection
within 15
point or any place where batteries/rechargeable batteries are sold!
seconds to
deactivate the
You thus fulfi l the legal requirements and make your contribution to protecting the environment!
ceiling alarm
If you don't deactivate

Technical Data

the ceiling alarm within
15 seconds, the alarm
a) Ceiling alarm
tone will be triggered
Power supply ............................... 4 batteries/rechargeable batteries of type Baby/C
Power consumption .....................approx. 1.1 mA (standby mode) or max. 120 mA (alarm tone)
Battery life ....................................approx. 6 months
PIR sensor angle .........................360°
Alarm ...........................................Piezoalarm, 100 dB(A)
b) IR remote control
Power supply ...............................1 battery, type "23A" (nominal voltage 12 V)
Power consumption .....................110 mA during transmission (key strokes)
c) General
Ambient temperature ...................Optimal: +20
At temperatures higher than +20 °C, the range or motion detection is reduced and worsened,
since the temperature difference between the moving object and the ambient/background tem-
perature is lower.
Ambient air humidity ....................0% to 70% relative air humidity, not condensing
or via an external stabilised power supply unit (not enclosed, ordered
separately), 9 V/DC, min. 200 mA; round plug 5.5/2.1 mm, outer contact
plus/+, inner contact minus/-
Permitted: +10 °C to +35 °C
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis