efficiency can be boosted, save energy for the earth, save money
for you.
1.
Open the door for the water tank
2.
Take out the water tank
3.
Unscrew the tap for the tank and fill up the tank with clean
water
NOTICE:
This efficiency feature by adding water is proposed to do after
one hour operation.
NOTICE !
1.
To prolong the compressor's life, after switch-off of the
unit, please wait for 3 minutes (at least) before re-switch.
2.
The cooling system will switch off if the ambient
temperature is lower than the set one. The ventilation,
however, keeps working on the set level. If the ambient
temperature rises above the selected level, the cooling will
return to work.
3.
On the contrary, the heating will switch off if the ambient
temperature is higher than the set one (still, the ventilation
keeps working on the set level). As the ambient
temperature drops below the selected level, the heating
will return to work.
4.
This machine is equipped with ANTI-FROST function.
While using the heating function during low temperature,
sometimes the heating will stop for a while in order to melt
the frost. As this occurs, just wait for the heating returns
to work.
DRAINAGE
During the process of cooling, some water will be extracted from
the air into the unit. If the tank is full, both of the compressor and
motor will stop. The "water full" sign will light on, also the
machine will beep as reminder.
To make the cooling work again, please empty the water by one of
the following ways:
Fig. 20
1.
Turn off the air conditioner and avoid moving it when full.
2.
Position a container (a water tray for example) underneath
the drain hole.
3.
Remove the drain knob & rubber plug from the drain hole
and allow the water to drain out.
4.
When the container is almost full, replace the rubber plug
in the drain hole and empty the water tray.
5.
Repeat until the unit is emptied.
6.
Replace the rubber plug and tighten the drain knob firmly.
7.
Switch on the unit - the full water or compressor operating
indicator should not be flashing.
If you wish to operate the unit without the need to empty the water
tank, please:
Fig 21.
Remove the drain knob and rubber plug and retain for
future use.
Connect the drain tube supplied to the water outlet as
shown and locate the other end into a drain.
Fig. 22.
The drain tube may be extended by adding an extension
tube and using a suitable connector.
Please note (Fig. 23.)
1.
The drain must be at or below the outlet level.
2.
Flashing comp / 'full water' indicator will not function in
this mode of drainage.
3.
If you want to extend the water tube, you can connect it
with another tube (OD: 18mm)

MAINTENANCE

Always unplug the air conditioner from the mains before
cleaning. To maximize the efficiency of the air conditioner
clean regularly.
Cleaning the housing
Use a soft, damp cloth to wipe the body clean.
Never use aggressive chemicals, gasoline, detergents, chemically
treated cloths, or other cleansing solutions. These all could
possibly hurt the cabinet.
Cleaning the filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust
and dirt from the filters and then rinse thoroughly under running
water (no hotter than 40oC).
Dry thoroughly before replacing.
Notice! Never operate the unit without the filters.
End of season storage (fig. 24)
Drain any water in the unit before completely operating the
unit on ventilation only mode for a few hours, to
thoroughly dry the inside.
Clean or change the filter
Unplug and store the power cord as shown
Cover the cord storage
Replace in the original carton or cover for storage.