CONTINUITY SOUND TEST
I Connection and specifications: idem Resistances
I Place the selector switch on the
I Continuous audible beep emitted for a resistance R < 80 Ω
BATTERY CHECKING
I Put the rotary switch on the function
I Short-circuit the leads, the needle must be positioned on the 0
(green square) of Ω green scale. In the contrary, change the battery.

4 - INFLUENCES

Additional uncertainty at the § 2 and § 3 uncertainty given :
TEMPERATURE
1%/10°C for all the ranges except 2%/10°C for 0.1V DC and 2.5%/
10°C for AC current ranges.
10%/10°C in Ω.
FREQUENCY
Voltage ranges :
-
In the bandwith 45Hz to 500Hz : 0%, except 1000V range : 0.5%
-
Outside the bandwith 45 to 500Hz and in the limits of § 3 bandwith:
1.5%, except 10V range : 4%.
Current ranges :
-
In the limit of § 3 bandwith : 1.5%

5 - GENERAL SPECIFICATIONS

Dimensions and weight
I 56 x 105 x 160 mm
Power supply
I One battery 9 V (type 6F22 or 6LF22 alkaline)
I Battery life:
- 10,000 measurements of 15 seconds with alkaline battery for
R > 50 Ω
- 4000 measurements of 5 seconds for R < 50 Ω (with beep)
Environmental conditions
I Temperature: use: -10°C to +55°C / storage: -40°C to +70°C
I Relative humidity:
use: ≤ 90% RH / storage: ≤ 95% RH
I Altitude: use < 2000 m
x 1 function
x 1 green.
I 500 g