Herunterladen Inhalt Inhalt Diese Seite drucken

Using The Gas Detector To "Feel Around" The Pipe; Technical Data - Herth+Buss SelectH2 mini Bedienungsanleitung

Klimaanlage
Vorschau ausblenden Andere Handbücher für SelectH2 mini:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instruction
9.3 Using the gas detector to
"feel around" the pipe
EN
Slowly "feeling around" the connection
points has proven successful in practice. This
is the best way to detect any small bubble of
gas escaping. Depending on the strength of
the gas concentration, the test process will
take around 2 – 3 seconds. When testing, this
means that briefly coming close to the fitting
or screw connection is not enough to detect
small gas leaks.
Gas
www.herthundbuss.com

10. Technical data

Detection range:
Resolution:
1 ppm / 0.1 vol % depending
Gas detection principle:
Time to stand-by:
Response time (T90):
W x H x D:
(with/without flexible sensor extension)
Net weight:
(without charging adapter)
Power consumption:
Battery life:
(with fully charged battery pack)
Concentration display:
Concentration values in ppm or vol % in LC
display.
Linear and cumulative display of the level of
detected concentration values via bar graph,
with up to 20 stages (segments, scale from
left to right up to 10,000 ppm)
Acoustic alarm:
Intermittent acoustic alarm (speed increases
as the detected concentration rises (can
be
switched
off));
concentration is > 4 vol % (LEL) (can be
switched off)
95980019
H
:1 ppm – 999 ppm
2
0.1 vol % – 4 vol %
on display range
MOX gas sensors
GGS 1000 and
GGS 6000 series
≤ 120 s
2 s
44 x 40 x 170 mm
approx. 260 g
approx. 0.8 VA (eff.)
approx. 8 h
continuous
tone
if