Please unfold page 3. Then you can always see the
operating elements and connections described.

1 Connections and Operating Elements

1.1 Camera with bracket, side view
1 Sunshield
2 Fixing screw for the sunshield
(the central screw of 3 screws)
After releasing the screw, the sunshield can be
removed backwards from the guide rail
3 Threaded jack [thread 6.3 mm (
the bracket when mounting the camera with sun-
shield to the ceiling
4 Connection cable, is connected to the jack TO
CAMERA (19) of the power supply unit
5 Cover, two magnets for zoom adjustment and
focus adjustment are below this cover (positions 10
and 11 in fig. 2)
6 Holding nut for the cover (5)
7 Knurled nut for locking
8 Setscrew for the joint of the bracket
9 Bracket
1.2 Camera, view from below
Cover (5) removed
10 Magnet: the focus can be adjusted by displacing
the magnet in the groove
11 Magnet: the focal length can be adjusted by dis-
placing the magnet in the groove
12 Threaded jack [6.3 mm (
the bracket to the lower side of the camera
1.3 Power supply unit
13 Power LED
14 POWER switch
15 Mains cable for connection to 230 V~/50 Hz
16 Fuse holder;
Only replace a blown fuse by one of the same type
17 Four sliding switches to adjust the power supply of
the camera
For the cameras TVCCD-190COL and TVCCD-
190HCOL a constant current of 450 mA must be
adjusted.
18 Video output for connection to a monitor
19 Connection jack for the camera
(video input and operating voltage output of the
camera)
1
/
")] for tightening
4
1
/
")] for tightly screwing
4

2 Safety Notes

The units (power supply unit and camera) correspond
to all required directives of the EU and are therefore
marked with
.
WARNING The power supply unit is supplied with
hazardous mains voltage (230 V~).
Leave servicing to skilled personnel
only. Inexpert handling or modification of
the unit may cause an electric shock
hazard.
It is essential to observe the following items:
G
The power supply unit is suitable for indoor use only.
G
Protect the units against extreme temperatures
(admissible ambient temperature range -10 °C to
+50 °C) and the power supply unit additionally
against dripping water and splash water and high air
humidity.
G
Do not place any vessels filled with liquid, e. g. drink-
ing glasses, on the power supply unit.
G
The camera housing is watertight according to IP 68,
with a maximum water depth of 1 m and a maximum
time of immersion of 2 days.
G
The heat being generated in the power supply unit
must be carried off by air circulation. Therefore, the
air vents at the housing must not be covered.
G
Do not insert anything into the air vents! This could
result in an electric shock.
G
Do not set the power supply unit into operation, and
immediately disconnect the mains plug from the
mains socket if
1. there is visible damage to the units or to the
mains cable,
2. a defect might have occurred after a drop or simi-
lar accident,
3. malfunctions occur.
The units must in any case be repaired by skilled
personnel.
G
A damaged mains cable must only be replaced by
skilled personnel.
G
Never pull the mains cable to disconnect the mains
plug from the mains socket, always seize the plug!
G
For cleaning do not use any aggressive detergents
or chemicals. For the power supply unit only use a
dry, soft cloth.
G
No guarantee claims for the power supply unit or the
camera and no liability for any resulting personal
damage or material damage will be accepted if the
power supply unit or the camera is used for other
purposes than originally intended, if they are not cor-
rectly connected, operated, or not repaired in an
expert way.