Herunterladen Inhalt Inhalt Diese Seite drucken

Axis P5512 Bedienungsanleitung Seite 10

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
Page 10
4. Route and connect the network cable and multi-connector cable, if applicable, to the network
camera. Be careful not to damage the cables when connecting them. Make sure the rubber
gasket holes are aligned with the cable tracks; if applicable, remove the cut-out piece for the
multi-connector cable from the rubber gasket.
5. Put the camera base lid back in its original position and fasten the screws.
6. Secure the camera using the supplied safety wire.
7. Slide the unit holders on the network camera into the slots on the mounting plate and rotate
the camera unit.
Drop ceiling mount
1. Remove the ceiling tile in which the drop ceiling mount is to be fitted.
2. Use the supplied template to mark the position for the 189.5 mm (7.5 in.) hole in the ceiling
tile. Cut around the template.
Notes:
• The combined weight of the camera and ceiling mount is approximately 2.3 kg (5.1 lb.). Check
that the ceiling material is strong enough to support this weight.
• The ceiling tile should be 5 mm–60 mm (0.2 in.–2.4 in.) thick.
3. Assemble the ceiling bracket.
4. Put the ceiling bracket into the ceiling tile. See illustration on page 11.
5. Tighten the bracket arm screws using a torx 20 screwdriver head.
6. Loosen the 4 camera base lid screws and remove the camera base lid. See illustration on page 7.
AXIS P5512 Installation Guide
Ceiling tile
Hole diameter
189.5 mm (7.5 in.)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis