The maintenance-free microprocessor-controlled room sensor AERASGARD
CO
content of the air within a range of 0...2000 ppm. The measurement value is converted into standard signal of 0 -10 V.
2
The maintenance-free microprocessor-controlled room sensor AERASGARD
switches) is used for detecting the CO
standard signal of 0 -10 V or 4...20 mA. Optional with traffic light indicator (five coloured LEDs).
Elegant enclosure made of plastic, with snap-on lid, based with 4-hole attachment, for installation on vertically or horizontally installed flush-
mounted boxes, with predetermined breaking point for surface-mounted connection or in enclosure made of stainless steel (top and bottom
parts are stainless steel, the cover is screwed on), vandal-proof version e.g. for schools, barracks and public buildings.
The CO
content of the air is measured using an optical NDIR sensor (non-dispersive infra-red technology). The detection range of the CO
2
is calibrated for standard applications such as monitoring residential rooms and conference rooms. Room ventilation on an as-needed basis,
improved well-being and customer benefit, increased comfort as well as reduced operating costs through energy conservation.
TECHNICAL DATA
Power supply:
Power consumption:
Sensor:
Measuring range:
Output:
Relay output:
Measuring accuracy:
Temperature dependence:
Pressure dependence:
Long-term stability:
Gas exchange:
Ambient temperature:
Warm up time:
Response time:
Electrical connection:
Enclosure:
Dimensions:
Installation:
Protection class:
Protection type:
Standards:
Optional:
®
AERASGARD
RCO
- SD – Room CO
2
AERASGARD
®
RCO
- W – Room CO
2
Type ⁄ WG02
Measuring Range
CO
2
RCO
- SD
(fixed)
2
R C O 2 - S D - U
0...2000 ppm
RCO
- W
(switchable)
2
R C O 2 -W
0...2000 ppm ⁄ 5000 ppm
RCO2-W VA
0...2000 ppm ⁄ 5000 ppm
RCO
- W - A
(switchable)
2
R C O 2 -W- A
0...2000 ppm ⁄ 5000 ppm
A = with "traffic light" (five coloured LEDs) for displaying the CO
Note:
This unit must not be used as safety-relevant device!
- W ⁄ RCO
- SD
2
2
content of the air within a range of 0...2000 ppm or 0...5000 ppm. The measurement value is converted into
2
24 V AC ⁄ DC (± 10 %)
< 1.5 W ⁄ 24 V DC typical; < 2.9 VA ⁄ 24 V AC typical; peak current 200 mA
Optical NDIR sensor (non-dispersive infra-red technology),
with manual calibration (via zero button),
RCO
- SD with automatic calibration (fixed)
2
RCO
- W with automatic calibration (can be deactivated via DIP switches)
2
RCO
- SD 0...2000 ppm (fixed)
2
RCO
- W 0...2000 ppm or 0...5000 ppm (selectable via DIP switches)
2
RCO
- SD 0 -10 V (fixed)
2
RCO
- W 0 -10 V or 4...20 mA, working resistance < 800 Ω (selectable via DIP switches),
2
with offset potentiometer (± 10 % of the measuring range)
RCO
- SD without changeover contact
2
RCO
- W with potential-free changeover contact 24 V
2
± 30 ppm ± 3 % of measured value
± 5 ppm ⁄ °C or ± 0.5 % of measured value ⁄ °C (whichever is higher)
± 0.13 % ⁄ mm Hg
< 2 % in 15 years
by diffusion
0...+ 50 °C
approx. 1 hour
< 2 minutes
0.14 - 1.5 mm
2
, via screw terminals
plastic, material ABS, colour pure white (similar to RAL 9010), stainless steel enclosure optional
85 x 85 x 27 mm (Baldur 1)
100 x 100 x 25 mm (stainless steel)
wall mounting or on in-wall flush box, Ø 55 mm, base with 4-hole for mounting on vertically or horizontally
installed in-wall flush boxes for cable entry from the back, with predetermined breaking point for on-wall
cable entry from top ⁄ bottom in case of plain on-wall installation
III (according to EN 60 730)
IP 30 (according to EN 60 529)
CE conformity, electromagnetic compatibility according to EN 61 326, EMC Directive 2014 ⁄ 30 ⁄ EU,
Low Voltage Directive 2014 ⁄ 35 ⁄ EU
with traffic light indicator (five coloured LEDs, see table) for displaying the CO
sensor and measuring transducer, Standard
2
sensor and measuring transducer, Premium
2
Output
CO
2
(fixed)
0 -10 V
(switchable)
0 -10 V ⁄ 4...20 mA
0 -10 V ⁄ 4...20 mA
(switchable)
0 -10 V ⁄ 4...20 mA
®
RCO
- SD with automatic calibration (fixed) is used for recording the
2
®
RCO
- W with automatic calibration (can be deactivated via DIP
2
Equipment
–
Changeover contact
Changeover contact, stainless steel enclosure
Changeover contact , LEDs
concentration.
2
Rev. 2018 - V31 GB
sensor
2
concentration
2
Item No.
(Baldur 1)
1501-61A0-1001-200
1501-61A0-7301-200
1501-61A0-7301-205
with traffic light
1501-61A0-7331-200