Herunterladen Inhalt Inhalt Diese Seite drucken
S+S REGELTECHNIK THERMASGARD TM 54 series Bedienungs- Und Montageanleitung

S+S REGELTECHNIK THERMASGARD TM 54 series Bedienungs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für THERMASGARD TM 54 series:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

D G F r
6000-3060-0000-1XX 30600-2019 V200 10 ⁄ 2018
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturmessumformer,
kalibrierfähig, mit Mehrbereichsumschaltung
und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature measuring transducer,
calibratable, with multi-range switching
and active output
F
Notice d'instruction
Convertisseur de température à immerger ⁄ à visser ⁄ en gaine,
étalonnable, avec commutation multi-gamme
et sortie active
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный преобразователь температуры,
калибруемый, с переключением между несколькими диапазонами
и активным выходом
TM 54
standard
(IP 54)
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
TM 54
TM 54
optional
(IP 65)
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für S+S REGELTECHNIK THERMASGARD TM 54 series

  • Seite 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Seite 2 D G F r TM 54 THERMASGARD ®  TM 54 Maßzeichnung Dimensional drawing Plan coté Габаритный чертеж ~ 80 M20 x1,5 TM 54 Aufsicht Top view Vue de dessus Вид сверху ø70 TM 54 ø6 Anschlusskopf Connecting head Tête de raccordement Соединительная...
  • Seite 3: Technische Daten

    THERMASGARD ® TM 54 Rev. 2019 - V20 Kalibrierfähiger Temperaturfühler THERMASGARD ® TM 54 mit acht umschaltbaren Mess bereichen, mit Anschlusskopf aus Aluminium, mit stetigem Ausgang für robuste Anwendungen mit separater Tauchhülse aus Edelstahl. Der Tauchfühler dient zur Erfassung von Temperaturen in flüssigen oder gasförmigen Medien.
  • Seite 4 Messumformer, kalibrierfähig, mit aktivem Ausgang Bürdendiagramm TEMPERATURBEREICHE: Bürdendiagramm Bei der Auswahl der Messumformerbereiche ist 4...20 mA darauf zu achten, dass die höchstzulässige Temperatur des Fühlers ⁄ Gehäuses nicht über schritten wird ! Umgebungstemperatur für den Messumformer: – 30 ...+ 70 °C zulässiger Bürdenwiderstand = siehe Bürdendiagramm Bereich...
  • Seite 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Achtung! Berücksichtigen Sie in jedem Fall die mechanischen und Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. thermischen Belastungsgrenzen der Schutzrohre nach DIN 43763 Folge schäden, welche durch Fehler an diesem Gerät entstehen, sind bzw.
  • Seite 6: Technical Data

    THERMASGARD ® TM 54 Rev. 2019 - V20 Calibratable temperature sensor THERMASGARD ® TM 54 with eight switchable measuring ranges, connecting head made of aluminium, continuous output, and separate stainless steel immersion sleeve for heavy-duty applications. This immersion sensor is used for the detection of temperatures in liquid or gaseous media.
  • Seite 7 Measuring transducers, calibrateable, with active output Load resistance diagram TEMPERATURE RANGES: Load resistance diagram When selecting measuring transducer ranges, 4...20 mA it is necessary to ensure that the maximum temperatures permissible for sensor ⁄ enclosure are not exceeded ! Ambient temperature for measuring transducers: –...
  • Seite 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices Attention! In any case, please observe the mechanical and thermal must only be connected to safety extra-low voltage. Consequential load limits of the protective tubes according to DIN 43763 or according damages caused by a fault in this device are excluded from war- to specific S+S standards! ranty or liability.
  • Seite 9: Carac Téristiques Techniques

    THERMASGARD ® TM 54 Rev. 2019 - V20 Sonde de température étalonnable THERMASGARD ® TM 54, avec huit plages de mesure commutables, tête de raccordement en aluminium, avec sortie analogique, conçue un usage intensif, avec doigt de gant séparé en acier inox. La sonde à plongeur sert à la mesure de la température, en milieux liquides ou gazeux.
  • Seite 10 Convertisseur de mesure étalonnable avec sortie active Load resistance diagram PLAGES DE TEMPÉRATURE (TB): Diagramme de charge Lors de la sélection des plages de convertisseur, 4...20 mA il faut veiller à ce que la température maximale admissible de la sonde ⁄ du boîtier ne soit pas dépassée ! Température ambiante du convertisseur: –...
  • Seite 11 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Les thermomètres doivent être installés conformément aux paramètres techniques disponibles et aux conditions réelles d'utilisation, en particulier : Veillez à ne brancher l’appareil que sur un réseau de très basse tension –...
  • Seite 12: Те Хнические Д Анные

    THERMASGARD ® TM 54 Rev. 2019 - V20 Калибруемый датчик температуры THERMASGARD ® TM 54 с переключением между восьмью диапазонами измерения, с присоединительной головкой из алюминия, постоянным выходом для жесткого крепления, с отдельной погружной гильзой из высококачественной стали. Погружной датчик служит для измерения температуры в жидких и газообразных средах. Используется в трубопроводах, отопительных системах, коллекторах, теплоцентралях, системах...
  • Seite 13: Напряжение Питания

    Преобразователи измерительные, калибруемые, с активным выходом Load resistance diagram ТЕМПЕРАТУРНЫЕ ДИАПАЗОНЫ: Нагрузочная диаграмма При выборе диапазона для измерительного преобразователя 4...20 мA следует учитывать, что не разрешается превышение максимальной допустимой температуры датчика  ⁄ корпуса ! Температура окружающей среды для измерительного преобразователя: –...
  • Seite 14 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Монтаж следует осуществлять с учетом соответствия прилагаемых технических параметров термометра реальным условиям эксплуатации, Подключение должно осуществляться исключительно к безопасно в особенности: малому напряжению. Повреждения приборов вследствие – диапазона измерения; несоблюдения...
  • Seite 15 D G F r THERMASGARD ®  TM 54 + MF - 06 - M Kanaltemperatur - TM 54 + fühler mit Montage- TH ⁄ xx ⁄ 90 flansch aus Metall TM 54 + Edelstahltauchhülse Duct temperature TM 54 + mit Halsrohr TH - VA ⁄...
  • Seite 16 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.

Inhaltsverzeichnis