BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
4
Installation and connection (continued)
4.4

Electrical connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-3.
Note the information on shielding and cable
routing on page 12.
S32
KA
Pin
Cable color
-C508
1
YE yellow
0...20 mA
GY gray
2
3
PK pink
0...10 V
4
RD red
5
GN green
6
BU blue
7
BN brown
8
WH white
Unassigned leads can be connected to the GND on the controller side but
1)
not to the shield.
2)
Factory setting, can be freely configured with the PC software.
Referred to as output 2 in PC software.
3)
4)
Reference potential for supply voltage and EMC-GND.
Tab. 4-3:
Pin assignment of connector S32/KA_ _
www.balluff.com
-C509
-C512
0...20 mA
20...0 mA
20...0 mA
2)
2)
2)
10...0 V
0...10 V
3)
3)
3)
Fig. 4-9: Pin assignment of S32 connector (view of connector pins of
transducer)
BTL7-... interface
-C513
-E508
-E509
4...20 mA
4...20 mA
2)
2)
0 V
10...0 V
0...10 V
10...0 V
3)
3)
La (communication line)
Not used
1)
GND
4)
10...30 V
Lb (communication line)
-E512
-E513
20...4 mA
20...4 mA
2)
2)
2)
0...10 V
10...0 V
3)
3)
3)
english