BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
3

Construction and function

Output signal rising:
Error signal
100 %
0 %
Null point
1)
12
72
Groove
~80
~23
max. 7
Fig. 3-1: BTL7-... transducer, construction
3.1

Construction

Electrical connection: The electrical connection is made
via a cable or a connector (see Type code breakdown on
page 21).
Housing: Aluminum housing containing the waveguide
and processing electronics.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on
page 18).
Nominal length: To optimally adapt the transducer to the
application, nominal lengths from 50 mm to 7620 mm are
available.
www.balluff.com
End point
Nominal length =
Measuring range
2)
~250
~250
Mounting clamps with insulating bushes
and ISO 4762 M5x22 cylinder-head screws,
max. tightening torque 2 Nm
1) Unusable area
2) Not included in scope
of delivery
1)
73
BTL5-P-3800-2 magnet
~80
15
english
2)
35
50
68
7