BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
6
Configuration with the Micropulse Configuration Tool
6.1
Value table for factory setting
Output gradient
Transducer
Rising
BTL7-C...
BTL7-E...
Falling
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for factory settings
NOTICE
Interference in function
Configuration with the Micropulse Configuration Tool
while the system is running may result in malfunctions.
► Stop the system before configuration.
6.2
Micropulse Configuration Tool
The BTL7-C/E5_ _-... transducer can be configured
quickly and simply on a PC using the Micropulse
Configuration Tool PC software.
The most important features include:
–
Online display of the current position of the magnet
–
Graphical support for setting the functions and curves
–
Display of information on the connected transducer
–
Selectable number formats and units for display
–
Resetting to factory settings is possible
–
Demo mode without having transducer connected
The PC software and associated manual can be
found in the Internet under www.balluff.com.
14
english
Unit
Min. value
Null value
mA
0
mA
3.2
4.0
mA
20.4
20.0
mA
20.4
20.0
6.3
With a BTL7-C/E5_ _-...-S32 transducer (with connector),
the communication box must be looped in between the
transducer and controller. The communication box is
connected to the PC via a USB cable.
Connection cable approx.
0.3 m with S32 (female)
connector
Fig. 6-1: Connecting the communication box with a connector
With a BTL7-C/E5_ _-...-KA_ _ transducer, the
communication lines La, Lb and GND must be connected
to the USB communication box.
Fig. 6-2: Connecting the communication box with a cable connection
End value
Max. value
0
20.0
20.4
20.0
20.4
0
4.0
3.2
Connecting the USB communication box
USB cable
8-pin
8-pin
USB cable
When reading or writing data via the
Configuration Tool, LED 2 flashes green.
Error value
20.4
20.4
0
0
3.2
Connection cable
approx. 0.3 m with
S32 (male) connector
Controller
6-pin
Controller
Connection cable
approx. 0.6 m with
luster terminal