Example of connections for IRON I sauna heaters
6,0 / 7,5 / 9,0 kW
Saunaheizgerät
Sauna heater
Poêle de sauna
Печь для сауны
6,0 kW
400 V AC 3N
U V W N PE
zum Steuergerät / control unit

Technical speci cations

Heater power as
Heater dimensions
per DIN
H/W/D in cm
6,0 kW
7,5 kW
64 / 44 / 33
9,0 kW
All information on cable cross-sections are minimum cross-sections in mm² copper line.
Leakage current: max. 0.75 mA per kW of heating power.
to be used with control units: that comply with the Low-Voltage Directive 2014/35/EU and the standards: DIN EN 60335-1, DIN EN 60335-2-53, DIN EN
62233, DIN EN 62233 Ber.1 and a sauna operation control range up to max. 115°C, and a sensor system with a safety temperature limiter of max.
24
Saunasteuergerät
Control unit
Boîtier de commande
Пульт управления
5
Netz / Mains / Réseau / Сеть
zum Steuergerät / control unit
Minimum dimensions
for sauna cabin
of air intake and
volume
rocks and packaging
exhaust vents
6 - 8 m³
35 x 4 cm
8 - 12 m³
35 x 5 cm
9 - 14 m³
35 x 6 cm
4
5
Attention!
Always connect the neutral wire N.
7,5 kW
400 V AC 3N
U V W N PE
Stone lling
Weight without
(not included in the
connection
delivery)
400 V 3N AC
13 kg
15 kg
GB
9,0 kW
400 V AC 3N
U V W N PE
zum Steuergerät / control unit
Connection power
electrical
Fuse protection of
supply - power
controller, A
extension
3 x 16
5 x 2,5
50 Hz
Connection control-
ler - heater
5 x 1,5
142°C.