Herunterladen Inhalt Inhalt Diese Seite drucken

Carrier GCV R 3H Bedienungsanleitung Seite 8

Luftkondensatoraggregat hermetische scroll-verdichter
Inhaltsverzeichnis
CARACTERISTIQUES TECHNIQUES
TECHNICAL DATA
TECHNISCHE DATEN
APPLICATION MOYENNE TEMPERATURE
GCV R 3H
Puissance frigorifique nominale
cooling capacity
Kälteleistung, nominal
Puissance absorbée nominale
input power
Leistungsaufnahme, nominal
Nombre
Number
Anzahl
Compresseur
Compressor
Type
Verdichter
Type
Typ
DESP 97/23/CE
Cat. Risque
PED 97/23/EC
Std
Risk Cat.
DGRL 97/23/EG
Risikokategorie
Niveau sonore
Std
Sound level
Version SI
Schalldruckpegel
Aspiration
Suction
Raccordements
Sauggas
Connections
Liquide
Anschlüsse
Liquid
Flüssigkeit
Intensités totales
Id
Total current
Stromaufnahme
Imax
insgesamt
Volume
Option BACL (6)
Volume
Inhalt
Puissance récupérée
Recovered capacity
Leistungsrück gewinnung
Débit d'eau
45/50°C
(7)
Water flow
Wasser durchsatz
∆P eau
∆P water
(1)
∆P Wasser
Puissance récupérée
Recovered capacity
Leistungsrück gewinnung
Débit d'eau
50/60°C
(7)
Water flow
Wasser durchsatz
∆P eau
∆P water
(1)
∆P Wasser
Standard
Standard
Standard
Option
Option
Optionen
Nbre ventilateurs
Number fans
Anzahl Lüfter
Débit d'air
Air flow
Luftvolumenstrom
Vitesse de rotation
Rotation speed
Drehzahl
Dimensions
Dimensions
(8)
Abmessungen
Poids (sans option)
Weight (without option)
Gewicht (nicht option)
(1) Puissance pour modèle en version standard au R404A aux conditions
nominales : Température d'évaporation -10°C. Température extérieure +32°C.
Surchauffe 20K. Sous-refroidissement 0K.
2) Catégorie de risque du groupe standard sans option.
La catégorie de risque globale de l'ensemble " Groupe avec options et
réservoir " est égale à la catégorie de risque la plus élevée des composants. Si
l'option réservoir 140 l est choisie, la catégorie de risque du groupe est IV.
(3) Les niveaux de pression acoustique (en dBA à 10 mètres) sont indiqués en
champ libre.
Le fonctionnement à un régime différent de ces conditions nominales peut
conduire à des résultats différents.
Les résultats obtenus sur le lieu de l'installation peuvent être différents
par rapport aux valeurs du catalogue, du fait de phénomènes de réflexion
(présence de mur, etc ...).
L'affaiblissement du niveau sonore en fonction de la distance est théorique et
les phénomènes de réflexion et de résonnance peuvent modifier le résultat, soit
au niveau global pondéré, soit sur certaines fréquences.
Std : Centrale standard.
Option SI : Coque isophonique sur compresseur.
(4) Intensité de démarrage (courant rotor bloqué).
(5) Intensité max. de fonctionnement pour groupe standard.
(6) Option BACL : Bouteille anti-coup de liquide.
(7) Option DESUR : Désurchauffeur
Circulation à contre-courant
Puissance désurchauffeur à +/-10% avec tous les compresseurs en
fonctionnement et utilisation eau claire.
Le fonctionnement à un régime différent de ces conditions nominales peut
conduire à des résultats différents.
Si application différente par rapport à la documentation : nous consulter pour
obtenir les caractéristiques du désurchauffeur.
8
(8) Dimensions : voir page 13
MEDIUM TEMPERATURE APPLICATION
ZB29
ZBD29
Nominal
(1)
kW
21,70
Nominal
(1)
kW
9,13
3
ZB29
KCE
ZBD29
(2)
III
(3) dB(A)
45
(3) dB(A)
38
inch
1"5/8
inch
7/8"
(4)
A
72
(5)
A
32
dm
8
3
kW
6,9
m³/h
1,1
kPa
1,8
kW
5,6
m³/h
0,5
kPa
0,5
dm
3
43
67
dm
3
99
Std
2xPM Y 2xPM Y 2xPM
SI
2xPM Y 2xPM Y 2xPM
Std
m³/h
16400
16400
SI
m³/h
16400
16400
Std tr/mn
720
rpm
SI
720
Std
1
Fig
SI
1
Std
kg
1251
SI
kg
1441
(1) Nominal capacities for standard model with R404A : Saturated suction
temperature -10°C. Outside temperature +32°C.
Superheat 20K. Subcooling 0K.
2) Pack system risk category (without option).
The global risk category of the "Pack with options and receiver" package is
equal to the higher risk category of the components. If option receiver 140 l is
choosen, risk category of unit is IV.
(3) The sound presure levels (in dB(A) at 10 meters) are mentioned in free field.
Running the equipment in conditions differing from these nominal values may
lead to different results.
The results obtained on the installation site may differ from those in this leaflet,
due to sound reflections from walls, etc.
The reduction of sound level as a function of distance is theoretical and sound
reflection and resonance may alter the results, either on total sound level or on
certain frequencies.
(4) Locked Rotor current.
(5) Max. operating current for standard pack.
(6) Option BACL : Suction accumulator
(7) Option DESUR : Desuperheat
Opposed-flow circulation
Desuperheater capacity +/- 10% with all running compressors and clear water.
Running the equipment in conditions differing from these nominal values may
lead to different results.
If other applying, contact us in view to obtain desuperheater characteristics.
(8) Dimensions : see page 13
R404A
ZB38
ZB45
ZBD45
ZB48
21,70
25,93
29,66
29,66
9,13
11,99
14,20
14,20
2+1
3
3
2+1
ZB29
ZB38
ZB45
ZB45
KCE
KCE
KCE
KCE
ZBD45
KCE
KCE
III
III
III
III
45
48
48
48
38
43
43
43
1"5/8
1"5/8
1"5/8
1"5/8
7/8"
7/8"
7/8"
7/8"
70
94
103
101
30
41
42
39
8
9
9
9
6,9
8,4
9,8
9,8
1,1
1,4
1,7
1,7
1,8
2,8
3,8
3,8
5,6
6,8
7,9
7,9
0,5
0,7
0,8
0,8
0,5
0,7
0,9
0,9
43
43
43
43
67
67
67
67
99
99
99
99
2xMM Y 2xMM Y 2xMM Y 2xMM
2xPM
2xPM
2xPM
2xPM
2xPM
20200
20200
20200
19600
20200
20200
20200
17200
720
910
910
910
720
910
910
910
1
1
1
1
1
1
1
1
1251
1272
1279
1279
1441
1462
1469
1469
Std : Standard pack.
Option SI : Sound reduction shell.
NORMALKÜHLUNG
ZB57
ZBD57
ZB66
ZB76
36,79
40,97
40,97
46,40
15,27
16,72
16,72
19,94
3
3
2+1
3
ZB48
ZB57
ZB57
ZB66
KCE
KCE
KCE
KCE
ZBD57
KCE
III
III
III
III
51
52
52
55
44
44
44
41
2"1/8
2"1/8
2"1/8
2"1/8
1"1/8
1"1/8
1"1/8
1"1/8
132
140
140
151
45
56
56
58
9
9
9
18
11,8
13,2
13,2
14,5
2,0
2,2
2,2
2,5
5,5
7,0
7,0
8,5
9,5
10,7
10,7
11,7
1,0
1,1
1,1
1,2
1,4
1,8
1,8
2,1
43
43
43
43
67
67
67
67
99
99
99
99
2xMM
3xPM Y 3xPM Y 3xPM
2xPM
2xPM
19600
19600
23600
23600
17200
17200
20400
20400
1110
1110
1110
1360
910
910
910
720
1
1
1
1
1
1
1
1
1273
1281
1281
1332
1462
1470
1470
1546
(1) Leistung für Modell in Standardausführung mit R404A bei
Nominalbedingungen: Verdampfungstemperatur -10 °C.
Außentemperatur +32 °C.
Überhitzung 20 K. Unterkühlung 0 K.
(2) Risikokategorie des Standardaggregats ohne Option.
Die Gesamt-Risikokategorie der kompletten "Einheit mit Optionen und
Sammler" entspricht der höchsten Risikokategorie der Komponenten. Wenn die
Option mit 140-l-Sammler gewählt wird, hat die Einheit die Risikokategorie IV.
(3) Die Schalldruckpegel (in dBa in 10 m Entfernung) sind Freifeldangaben.
Bei von diesen Nominalbedingungen abweichendem Betrieb kann es zu
anderen Ergebnissen kommen.
Die am Installationsort erzielten Ergebnisse können aufgrund von Reflexionen
(an Wänden usw.) von den Katalogwerten abweichen.
Die Abschwächung des Schalldruckpegels mit zunehmender Entfernung ist
theoretisch, und Schallreflexionen und Resonanzerscheinungen können das
Ergebnis verändern, sowohl im Ganzen wie auch bei bestimmten Frequenzen.
Std: Standardsystem.
Option SI: Schallschutzhaube am Verdichter.
(4) Stromstärke bei Anlauf (bei blockiertem Rotor)
(5) Max. Betriebsstrom für Standardaggregat.
(6) Option BACL: Flüssigkeitsabscheider
(7) Option DESUR: Enthitzer
Gegenstrom-Zirkulation
Enthitzerleistung bei +/-10 % mit allen Kompressoren in Betrieb und
Verwendung von klarem Wasser.
Bei von diesen Nominalbedingungen abweichendem Betrieb kann es zu
anderen Ergebnissen kommen.
Bei von der Dokumentation abweichenden Anwendungen: Bitte kontaktieren
Sie uns wg. der Technischen Daten des Enthitzers.
(8) Abmessungen: siehe Seite 13.
ZB95
ZB114
53,43
67,60
77,86
23,72
29,30
36,52
3
3
3
ZB76
ZB95
ZB114
KCE
KCE
KCE
III
III
III
55
57
59
41
46
46
2"1/8
2"5/8
2"5/8
1"1/8
1"3/8
1"3/8
164
204
249
67
93
108
18
18
18
16,8
21,3
24,8
2,9
3,6
4,3
11,7
9,0
12,3
13,5
17,3
20,0
1,4
1,8
2,1
2,9
2,2
3,1
43
67
67
67
99
99
99
140
140
3xMM
3xMM
3xPM
35400
35400
25800
25800
1360
1360
1360
720
910
910
1
1
1
1
1
1
1356
1404
1414
1570
1593
1603
Inhaltsverzeichnis
loading