APPLICATION MOYENNE TEMPERATURE
GCV R 2H
Puissance frigorifique nominale
Nominal
cooling capacity
Kälteleistung, nominal
Puissance absorbée nominale
Nominal
input power
Leistungsaufnahme, nominal
Nombre
Number
Anzahl
Compresseur
Compressor
Type
Verdichter
Type
Typ
DESP 97/23/CE
Cat. Risque
PED 97/23/EC
Std
Risk Cat.
DGRL 97/23/EG
Risikokategorie
Niveau sonore
Std
Sound level
Version SI
Schalldruckpegel
Aspiration
Suction
Raccordements
Sauggas
Connections
Liquide
Anschlüsse
Liquid
Flüssigkeit
Intensités totales
Id
Total current
Stromaufnahme
Imax
insgesamt
Volume
Option BACL (6)
Volume
Inhalt
Puissance récupérée
Recovered capacity
Leistungsrück gewinnung
Débit d'eau
45/50°C
(7)
Water flow
Wasser durchsatz
∆P eau
∆P water
(1)
∆P Wasser
Puissance récupérée
Recovered capacity
Leistungsrück gewinnung
Débit d'eau
50/60°C
(7)
Water flow
Wasser durchsatz
∆P eau
∆P water
(1)
∆P Wasser
Standard
Standard
Standard
Option
Option
Optionen
Nbre ventilateurs
Number fans
Anzahl Lüfter
Débit d'air
Air flow
Luftvolumenstrom
Vitesse de rotation
Rotation speed
Drehzahl
Dimensions
Dimensions
(8)
Abmessungen
Poids (sans option)
Weight (without option)
Gewicht (nicht option)
(1) Puissance pour modèle en version standard au R404A aux conditions
nominales : Température d'évaporation -10°C. Température extérieure +32°C.
Surchauffe 20K. Sous-refroidissement 0K.
2) Catégorie de risque du groupe standard sans option.
La catégorie de risque globale de l'ensemble " Groupe avec options et
réservoir " est égale à la catégorie de risque la plus élevée des composants. Si
l'option réservoir 140 l est choisie, la catégorie de risque du groupe est IV.
(3) Les niveaux de pression acoustique (en dBA à 10 mètres) sont indiqués en
champ libre.
Le fonctionnement à un régime différent de ces conditions nominales peut
conduire à des résultats différents.
Les résultats obtenus sur le lieu de l'installation peuvent être différents
par rapport aux valeurs du catalogue, du fait de phénomènes de réflexion
(présence de mur, etc ...).
L'affaiblissement du niveau sonore en fonction de la distance est théorique et
les phénomènes de réflexion et de résonnance peuvent modifier le résultat, soit
au niveau global pondéré, soit sur certaines fréquences.
Std : Centrale standard.
Option SI : Coque isophonique sur compresseur.
(4) Intensité de démarrage (courant rotor bloqué).
(5) Intensité max. de fonctionnement pour groupe standard.
(6) Option BACL : Bouteille anti-coup de liquide.
(7) Option DESUR : Désurchauffeur
Circulation à contre-courant
Puissance désurchauffeur à +/-10% avec tous les compresseurs en
fonctionnement et utilisation eau claire.
Le fonctionnement à un régime différent de ces conditions nominales peut
conduire à des résultats différents.
Si application différente par rapport à la documentation : nous consulter pour
obtenir les caractéristiques du désurchauffeur.
(8) Dimensions : voir page 13
MEDIUM TEMPERATURE APPLICATION
R404A
ZB29
ZBD29
ZB38
(1)
kW
15,24
15,24
(1)
kW
5,63
5,63
2
1+1
ZB29
ZB29
KCE
KCE
ZBD29
KCE
(2)
III
III
(3) dB(A)
43
43
(3) dB(A)
37
37
inch
1"3/8
1"3/8
inch
7/8"
7/8"
(4)
A
62
60
(5)
A
22
20
dm
8
8
3
kW
4,5
4,5
m³/h
0,8
0,8
kPa
2,2
2,2
kW
3,6
3,6
m³/h
0,4
0,4
kPa
0,5
0,5
dm
3
43
43
67
67
dm
3
99
99
Std
2xPM Y 2xPM Y 2xPM Y 2xPM Y 2xPM Y 2xPM
SI
2xPM Y 2xPM Y 2xPM Y 2xPM Y 2xPM Y 2xPM
Std
m³/h
16400
16400
16400
SI
m³/h
16400
16400
16400
Std tr/mn
720
720
rpm
SI
720
720
Std
1
1
Fig
SI
1
1
Std
kg
1198
1198
SI
kg
1389
1389
(1) Nominal capacities for standard model with R404A : Saturated suction
temperature -10°C. Outside temperature +32°C.
Superheat 20K. Subcooling 0K.
2) Pack system risk category (without option).
The global risk category of the "Pack with options and receiver" package is
equal to the higher risk category of the components. If option receiver 140 l is
choosen, risk category of unit is IV.
(3) The sound presure levels (in dB(A) at 10 meters) are mentioned in free field.
Running the equipment in conditions differing from these nominal values may
lead to different results.
The results obtained on the installation site may differ from those in this leaflet,
due to sound reflections from walls, etc.
The reduction of sound level as a function of distance is theoretical and sound
reflection and resonance may alter the results, either on total sound level or on
certain frequencies.
Std : Standard pack.
Option SI : Sound reduction shell.
(4) Locked Rotor current.
(5) Max. operating current for standard pack.
(6) Option BACL : Suction accumulator
(7) Option DESUR : Desuperheat
Opposed-flow circulation
Desuperheater capacity +/- 10% with all running compressors and clear water.
Running the equipment in conditions differing from these nominal values may
lead to different results.
If other applying, contact us in view to obtain desuperheater characteristics.
(8) Dimensions : see page 13
CARACTERISTIQUES TECHNIQUES
TECHNISCHE DATEN
ZB45
ZBD45
ZB48
ZB57
18,08
20,84
20,84
24,13
7,56
8,89
8,89
10,40
2
2
1+1
2
ZB38
ZB45
ZB45
ZB48
KCE
KCE
KCE
KCE
ZBD45
KCE
III
III
III
III
45
46
46
48
38
38
38
43
1"3/8
1"3/8
1"3/8
2"1/8
7/8"
7/8"
7/8"
1"1/8
80
89
88
118
27
28
26
31
8
9
9
9
5,4
6,3
6,3
8,1
0,9
1,1
1,1
1,3
3,2
4,4
4,4
2,6
4,4
5,1
5,1
6,6
0,5
0,5
0,5
0,6
0,8
1,1
1,1
0,7
43
43
43
43
67
67
67
67
99
99
99
99
∆
2xPM
∆
2xPM
16400
16400
20200
20200
16400
16400
20200
20200
720
720
720
910
720
720
720
910
1
1
1
1
1
1
1
1
1213
1213
1217
1217
1403
1403
1407
1407
(1) Leistung für Modell in Standardausführung mit R404A bei
Nominalbedingungen: Verdampfungstemperatur -10 °C.
Außentemperatur +32 °C.
Überhitzung 20 K. Unterkühlung 0 K.
(2) Risikokategorie des Standardaggregats ohne Option.
Die Gesamt-Risikokategorie der kompletten "Einheit mit Optionen und
Sammler" entspricht der höchsten Risikokategorie der Komponenten. Wenn die
Option mit 140-l-Sammler gewählt wird, hat die Einheit die Risikokategorie IV.
(3) Die Schalldruckpegel (in dBa in 10 m Entfernung) sind Freifeldangaben.
Bei von diesen Nominalbedingungen abweichendem Betrieb kann es zu
anderen Ergebnissen kommen.
Die am Installationsort erzielten Ergebnisse können aufgrund von Reflexionen
(an Wänden usw.) von den Katalogwerten abweichen.
Die Abschwächung des Schalldruckpegels mit zunehmender Entfernung ist
theoretisch, und Schallreflexionen und Resonanzerscheinungen können das
Ergebnis verändern, sowohl im Ganzen wie auch bei bestimmten Frequenzen.
(4) Stromstärke bei Anlauf (bei blockiertem Rotor)
(5) Max. Betriebsstrom für Standardaggregat.
(6) Option BACL: Flüssigkeitsabscheider
(7) Option DESUR: Enthitzer
Gegenstrom-Zirkulation
Enthitzerleistung bei +/-10 % mit allen Kompressoren in Betrieb und
Verwendung von klarem Wasser.
Bei von diesen Nominalbedingungen abweichendem Betrieb kann es zu
anderen Ergebnissen kommen.
Bei von der Dokumentation abweichenden Anwendungen: Bitte kontaktieren
Sie uns wg. der Technischen Daten des Enthitzers.
(8) Abmessungen: siehe Seite 13.
TECHNICAL DATA
NORMALKÜHLUNG
ZBD57 ZB66
ZB76
ZB95
26,86
26,86
29,60
36,73
11,34
11,34
14,00
15,23
2
1+1
2
2
ZB57
ZB57
ZB66
ZB76
KCE
KCE
KCE
KCE
ZBD57
KCE
III
III
III
III
49
49
50
50
43
43
44
44
2"1/8
2"1/8
2"1/8
2"1/8
1"1/8
1"1/8
1"1/8
1"1/8
122
122
131
141
38
38
38
44
9
9
9
9
9,1
9,1
10,0
11,7
1,5
1,5
1,7
2,0
3,2
3,2
3,9
5,4
7,4
7,4
8,1
9,5
0,7
0,7
0,8
0,9
0,8
0,8
1,0
1,4
43
43
43
43
67
67
67
67
99
99
99
99
∆
∆
∆
∆
2xPM
2xPM
2xPM
2xMM
∆
∆
∆
∆
3xPM Y 3xPM Y
2xPM
2xPM
2xPM
20200
20200
17200
23600
20200
20200
17200
20400
910
910
910
910
910
910
910
910
1
1
1
1
1
1
1
1
1227
1227
1261
1272
1417
1417
1451
1462
Std: Standardsystem.
Option SI: Schallschutzhaube am Verdichter.
ZB114
44,96
51,76
19,59
24,42
2
2
ZB95
ZB114
KCE
KCE
III
III
55
57
40
42
2"1/8
2"1/8
1"1/8
1"1/8
174
213
62
72
18
18
14,2
16,4
2,4
2,8
8,1
11,1
11,5
13,2
1,2
1,4
2,0
2,8
43
43
67
67
99
99
∆
∆
2xMM
23600
20400
1360
1360
720
720
1
1
1
1
1287
1290
1503
1505
7