The cooling device is equipped with an electronic device to protect against
reversing the polarity and short circuits when connecting to a battery.
To protect the battery, the cooling device switches off automatically if the
voltage is insufficient (see table below).
Switch-off voltage
Switch-on voltage
Connecting to 230 V mains supply
D
DANGER!
 Never handle plugs and switches with wet hands or if you are
standing in a puddle.
 If you are operating your cooling device on board a boat with
a mains connection of 230 V from the land, you must install
a ground protection circuit breaker between the 230 V mains
supply and the cooling device.
Seek advice from a trained technician.
➤ To operate the cooling device with a 230 V mains supply, use an WAECO
CoolPower EPS100W or MPS35 rectifier.
EN
Setting up and connecting the cooling device
12 V
10.4 V
11.7 V
24 V
22.8 V
24.2 V