6. Commissioning / 7. Electrical output
6. Commissioning
Avoid pressure spikes during the start-up phase
Install the pressure connection according to the symbols
GB
high pressure
j
Only commission the device if the pressure gauge is in a safe
and flawless condition
7. Electrical output (air2guide P+E)
Output signal
Power supply U
Accuracy
Electrical connection
Terminal configuration
Output signal 4 ... 20 mA, 2-wire
Output signal 0 ... 10 V, 3-wire
8
low pressure
i
4 ... 20 mA, 2-wire or
0 ... 10 V, 3-wire
4 ... 20 mA, 2-wire: 14 ... 35 V DC
B
0 ... 10 V, 3-wire: 15 ... 35 V DC
±3 % of full scale value
M12 cable connection with screw terminals
WIKA Operating instructions air2guide Models A2G-10 and A2G-15
Power supply
14 ... 35 V DC
Power supply
15 ... 35 V DC