6

Specifications

Electrical data
Output level
Output signal
Output frequency
Offset (static)
Amplitude tolerance
Amplitude ratio V
TR1
Supply voltage V
S
Power consumption without load
Mechanical data
Admissible air gap
Width of the target wheel
Material of the target wheel
Max. admissible cable length
Working temperature
Operating and storage temperature
Protection class
Electromagnetic compatibility
Insulation strength
Vibration resistance
Shock resistance
Weight
Housing
Connection
(1)
The normative limit values are met if mounting and connection jobs are carried out properly. Coaxial earthing of
the MiniCoder connection cable, e.g. on the free cable end will improve noise.
GEL 2442
/V
TR2
1 V
difference signal
pp
two 90° phase-shifted sinusoidal signals
and their inverse signals, short circuit
proof; optionally with reference pulse.
0... 200 kHz at a line capacity 5 nF
± 20 mV
- 20% to + 10%
0.9 .to 1.1
5 V DC ± 5 %
≤ 0.3 W
0.15 mm ± 0.02 mm with module 0.3
0.20 mm ± 0.03 mm with module 0.5
≥ 4.0 mm
Ferromagnetic steel
100 m (observe the voltage drop on the
power line)
- 30 °C to + 85 °C
- 40 °C to + 120 °C
IP 68
(1)
EN 61000-6-1 to 4
500 V, according to EN 60439-1
2
200 m/s
according to DIN EN 60068-2-6
2
2000 m/s
according to DIN EN
600068-2-27
30 g
Polyphenylene sulfide(PPS), glassfibre
reinforced
9-core cable, wire profile 0.15 mm
O.D. 5
mm, min. bending radius
–0.3 mm
25 mm.
Seperate screen connection line for near-
sensor earthing (e.g. using one fixing
screw)
6 Specifications
2
31