6.4 Load data
In dynamic operation, the following must be considered for the design:
6.4.1 Load data*
Version
Admissible forces (N)
Fx
RK Compact 30
50
RK Compact 50
125
RK Compact 80
215
RK Compact
215
* based on guidance slides (values static, guidance unit covering the whole area)
Mx
Fx max = m*a [m/s
Admissible torques (Nm)
Fy
Fz
Mx
160
160
3
350
350
6
600
600
12
1150
1150
32
Fy
6. Product Information
2
]
My
Mz
3
3
0.09
7.5
7.5
0.46
18
18
3.68
59
59
9.85
Fz
My
Mz
Area moment of inertia
4
(cm
)
0.90
7.44
47.14
214.84
Fx
37