SAFETY INSTRUCTIONS
General safety instructions
Assembly, installation, commissioning and repair of
electronic devices must be carried out by qualified
electricians. Observe the latest regulations and standards
for system installations.
WARNING! Danger due to electrical shock.
Observe the safety regulations according to DIN VDE
0100, when working on main power connections of 230 V.
When installing TCS:BUS systems the general safety
regulations for telecommunication systems according
to VDE 0800 must be observed. Inter alia:
> separated cable routing of high and low voltage lines,
> minimum distance of 10 cm in case of a common cable
routing,
> use of separators between high and low voltage lines within
shared cable ducts,
> use of standard telecommunication lines, e.g. J-Y (St) Y with
PRODUCT INFORMATION (BRIEF)
0.8 mm diameter
Series TASTA
> already existing lines (modernisation) with deviating
cross-sections can be used in compliance with the loop
Video indoor station for hands-free talking
resistance.
IVW5110-0145
Requirements to protect against lightning
IVW5111-0145
CAUTION! Device damage due to overvoltage.
German / English
By suitable lightning protection measures it has to be
ensured that the electric voltage of 32 V DC at each connec-
tion is not to be exceeded.
SCOPE OF DELIVERY
PRODUCT DESCRIPTION
1 x Indoor station IVW511x-0145
Intended use
1 x Mounting plate with connection terminal
1 x Product information (brief)
IVW511x-0145 is a video indoor station for hands-free talking.
1 x Instruction manual
It is suitable exclusively for operation at TCS:BUS. Type of
installation: surface-mount.
For applications, which differ from the intended use or
goes beyond it, the manufacturer accepts no liability.
PI_IVW511x-0145
System manual
DEVICE OVERVIEW
15
Sensor button contrast
14
Sensor button brightness
13
Call OFF button
12
Smart Slot
11
Indication ring tone
mute (LED red)
10
Volume button
9
Speech button
8
Indication for incoming calls /
speaking (LED green)
INDICATION AND OPERATING ELEMENTS
1 > shortly touch: adjustable in 8 steps
2 > shortly touch: video image of the front door camera is
displayed or switching-over between different cameras
3 > send control function 8, send internal call, door release
automatic on / off or call diversion on / of configurable
> ring tone selection: internal call
4 > switch light
> ring tone selection: floor call
> ambient illumination: press 4 s to de-/activate the
ambient illumination
5 > door release
> trigger light switch function, only if the light switch
function is activated in the front door station
> terminate speaking: voice connection is terminated
automatically after 4 s
> ring tone selection: door call 1 from the front door station
6 > OFF: door opener in standby
> LED is ON: automatic door release activated
> LED lights up for 3 s, door is opened
7
> ambient illumination is switched on, operational readiness
> blinks: a call is displayed, if configured
> OFF: temporary (manually) or permantently switched off
> ON: temporary (manually) or permantently switched on
8 > OFF: in standby
> LED is ON: call, speaking activated
> blinks 3 x: speech channel is busy
9 > shortly press: call acceptance, speaking activated
> press for 2 s: duplex communication is activated
> speaking terminated
> ring tone selection: door call 2 from front door station
10 > setting the ring tone volume in 4 steps, when no voice
connection is established
> setting the volume of the voice output in 4 steps in case
of an established voice connection
11 > OFF: ring tone mute is deactivated
> ON: ring tone mute is activated
> blinks: ring tone programming mode
> flashes: call diversion activated, ring tone mute deactivated
> LED turns off in longer periods: call diversion activated,
ring tone mute activated
12 > for additional signalling of door calls, can be ordered
as asseccory
13 > shortly press: ring tone mute activated
> press for 8 s: initiate / terminate ring tone selection
> terminate the duplex communication
14 > shortly touch: adjustable in 8 steps
15 > shortly touch: adjustable in 8 steps
TECHNICAL FEATURES
Supply voltage .................. +24 V ± 8 % (control unit)
6-wire operation .............. input current: I(a) = 0.13 mA
I(P) in standby: 3.18 mA
I(Pmax): 147.0 mA
Video module ................... TFT colour module
Display size ...................... 8.9 cm (3.5 inch)
Resolution ........................ 320 x 240 pixel, RGB
Video signal input ............ symmetrical 1 Vss FBAS
Floor video input .............. asymmetrical 1 Vss FBAS
Degree of protection ........ IP30
1
Sensor button colour
Acceptable ambient
temperature ..................... - 5 ...+ 40 °C
2
Sensort button
Housing ............................ plastics ASA
image activation
Dimensions (in mm) ........... H 194 x W 94 x D 17 (mounting plate),
D 21 (mounting tray)
Weight .............................. 221 g (incl. mounting plate)
3
Function button
INSTALLATION
4
Light switch button
Mounting height
For an optimal operation, install the video indoor station 1.60
m (upper egde of the device) above the ground.
5
Door release button
6
Indication for door
release (LED blue)
7
Ambient illumination
Install the mounting plate
Error detection and indication
Set a flush-mount socket to stow the cables. Connect the wires
Indication error mode, if error detected: All 3 LEDs are flashing.
to the terminals (a, b, E, P, P, M, V1 und V2). Screw the mounting
Pressing any button of the device triggers the output of an
plate to the flush-mount socket.
error tone.
Error tone - error causes and troubleshooting
Observe the installation position of the mounting plate.
It is marked by an arrow and the designation TOP.
The error tone sounds 1 x long and 3 x short:
> a- and P-wire are exchanged or short-circuited
> exchange a- and P-wire or remove short-circuit,
device is in standby mode again
The error tone sounds 1 x long and 2 x short:
> a-wire: not connected or not supplied
> connect a-wire or check power supply,
device is in standby mode again
The error tone sounds 1 x long and 1 x short:
> button stucks (pressed longer than 15 s)
> loosen the button at the device or the floor push button,
device is in standby mode again
Install the mounting tray
Matching resistor
If the installation of a flush-mounted socket is not
If the video indoor station is placed at the end of a strand or
possible, use the mounting tray. The mounting tray is
is the only device at the TCS:BUS, the matching resistor is
available as an accessory (article: ZIA5002-0145).
to be activated.
Remove the device
Ex works the video indoor station is not set up for the
Insert a screw driver with slight pressure into the release
operation at the end of the strand.
opening (1). Pull off the device to the front at its upper side.
Lift the device out of the adjustment increments (2).
Snap on the device
Put the device onto both adjustment increments of the mounting
plate (1). Press the device against the latch until it snaps on (2).
2
1
BELL BUTTON PROGRAMMING
Basic principle:
1
All devices at the TCS:BUS have an unique serial number.
The serial number of the indoor station is allocated to the bell
2
button of the front door station. The allocation is stored in the
remove the device
EEPROM of the front door station.
Requirements for the programming:
snap-on the device
> Ensure that the access to the indoor station in the flat is
Example circuit:
granted.
> Check if the indoor station is connected to the TCS:BUS.
> Switch on the mains voltage. The operating LED at the power
IVW5110
supply and control unit is on.
floor push
> Check if a programming lock is set. If the programming
button
lock is activated, you cannot program any bell button. To
deactivate the programming lock you need a Service Device
BVS20 NGV1011
TCSK or the configuration software configo
> For device-specific indication modes of the front door station
AVC11010
see product information of the front door station.
Speech button
Connecting the floor push button
Connect the floor push button to the terminals E – P an.
Alternatively you can connect the floor push button to
the terminals a – E. Ensure that the a-wire of the con-
trol unit is connected to the a-terminal of the indoor station.
COMMISSIONING
RUN/PROG button
Install all devices of the system completely. Check the a-,
b- and P-wire against each other on short-circuit. Switch on
the mains power.
LED
1. Control unit:
Switching on the programming mode of the systems
> shortly press the RUN/PROG button
> LED blinks
> programming mode is activated
2. Programming via voice connection
> press the speech button
> shortly press the bell button
> ring tone sounds at the front door and indoor station
> press the speech or door release button
3. Control unit:
Switching off the programming mode of the system
> shortly press the RUN/PROG button
> LED lights up
> programming mode is deactivated
Deleting bell buttons
> press the bell button that is to be deleted for around 6 seconds
until an acknowledgement tone sounds
> release the bell button
> previously execute step 1 and the step 3
Notes:
Do not press the RUN/PROG button longer than 5 seconds.
a)
Otherwise you will activate the light switch function of the
front door station. The bell button cannot be program
med. Repair:
> Wenn die LED blinkt, drücken Sie kurz die RUN/PROG-Tas-
te, um den Programmiermodus auszuschalten.
> Drücken Sie die RUN/PROG-Taste nur kurz, um den
Programmiermodus einzuschalten.
> Programmieren Sie dann die Klingeltaste.
Not necessary, if the bell buttons have not been program-
b)
med, see product information of the front door station.
If there sounds a Progsperr tone (long high tone followed
c)
deactivated
by long low tone) instead, the front door station is equip-
ped with a programming lockn. You can deactivate the
programming lock only with the service device TCSK or
the configuration software configo
Further information (parallel call with only one bell
button) can be found in the system manual, in the down-
load area at www.tcsag.de or by scanning the QR code.
activated
NOTES
Conformity
Declarations of conformity are available for
download www.tcsag.de.
Information of disposal
Dispose the device separately from domestic waste
via a collection point for electronic scrap. Ask your
county administration for the responsible collection
point.
Dispose the parts of the packaging in collecting
tanks for cardboard and paper resp. plastics.
Service
For detailed information visit our website www.tcsag.de.
.
Download or scan the QR code.
TM
HOTLINE
Fon +49 4194 9881-188,
Fax +49 4194 9881-189
E-Mail hotline@tcsag.de
SALES
ISW5110
Fon +49 4194 9881-144
Fax +49 4194 9881-149
E-Mail sales@tcsag.de
Bell button
TCS TürControlSysteme AG
Geschwister-Scholl-Straße 7
D-39307 Genthin, GERMANY
AVC11010
Fon: +49 3933 8799-10
Fax: +49 3933 8799-10
TCS Österreich GmbH
BVS20
Gewerbepark 21
A-2821 Lanzenkirchen, AUSTRIA
Printout: 05/2017 | Subject to technical changes.
kPI_IVW511x-0145 1 A
www.tcsag.de
a)
c)
e)
b)
c)
.
TM
ORDER DIVISION
Fon +49 4194 9881-166
Fax +49 4194 9881-169
E-Mail offer@tcsag.de
TRAINING COURSES
Fon +49 4194 9881-155
Fax +49 4194 9881-159
E-Mail schulungen@tcsag.de

Werbung

loading

Diese Anleitung auch für:

Ivw5111-0145